Key result
Flexible multi-sensor array enables 100% of inexperienced volunteers to record high-quality heart sounds for home monitoring.
Why the study?
Wearable home monitoring for chronic heart failure via cardiac time intervals is limited because recording high-quality phonocardiographic signals requires accurate stethoscope positioning unfeasible for naive users.
Does a wearable multi-sensor array enable inexperienced users to record good-quality heart sounds?
Observational (n=42)
Does a wearable multi-sensor array enable inexperienced users to record good-quality heart sounds?
A novel wearable multi-sensor array allows inexperienced users to record high-quality heart sounds, potentially enabling home monitoring for heart failure patients.
Answers are grounded in this paper and cite their sources.
Supports novice heart sound recording for home monitoring; leaves open validation and outcome impact in chronic heart failure.
The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon.
No takes yet. Share an insight, caveat, or question.
Giordano et al. (2023) conducted an observational in Chronic heart failure (n=42). Flexible multi-sensor array (multi-source PCG and ECG) was evaluated on Recording of signals of good to excellent quality. A flexible multi-sensor array enabled 100% of 42 inexperienced volunteers to record heart sound signals of good to excellent quality, indicating suitability for home monitoring.