Key result
PFA for AF linked to a small ~0.8°C median increase in esophageal temperature.
Why the study?
Preclinical animal studies reported a dose-dependent esophageal temperature rise with pulsed field ablation, but intraluminal esophageal temperature changes in a clinical setting remained to be evaluated.
Does pulsed field ablation cause significant intraluminal esophageal temperature rises in patients undergoing first-time ablation for atrial fibrillation?
Observational (n=43)
Does pulsed field ablation cause significant intraluminal esophageal temperature rises in patients undergoing first-time ablation for atrial fibrillation?
Pulsed field ablation for atrial fibrillation causes a small but significant rise in esophageal temperature in most patients, though temperatures over 40°C are rare and no clinical esophageal injuries were observed.
Answers are grounded in this paper and cite their sources.
Small esophageal temperature rises during pulsed field ablation were not linked to injury; leaves open confirmation of safety in larger cohorts.
INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.
No takes yet. Share an insight, caveat, or question.
Kirstein et al. (2023) conducted an observational in Atrial fibrillation (n=43). Pulsed field ablation (PFA) was evaluated on Intraluminal esophageal temperature (TESO) change (p=< .001). Pulsed field ablation for atrial fibrillation resulted in a small but significant median intraluminal esophageal temperature increase of 0.8 ± 0.6°C (p < 0.001), with rises over 40°C being rare.
Synapse has enriched 10 related papers. Consider them for comparative context: