Answers are grounded in this paper and cite their sources.
Evaluates 68Ga-PSMA-33's diagnostic potential in prostate cancer, suggesting improved tumor detection capabilities.
Purpose: this study aimed to investigate the potential of a novel 68Ga-labeled PSMA-targeted radiotracer, 68Ga-PSMA-33, as a diagnostic tool for prostate cancer in preclinical and pilot clinical studies. Methods: 68Ga-PSMA-33 was radiolabeled using an iQS-TS automated module, and its radiochemical purity and in vitro stability were analyzed via radio-HPLC. The specificity and binding affinity for PSMA were determined in LNCaP (PSMA+) cells. A head-to-head comparison with 68Ga-PSMA-617 was performed in murine models through biodistribution, pharmacokinetic, and micro-PET/CT imaging studies. The clinical phase involved 68Ga-PSMA-33 PET/CT imaging in seven patients with prostate cancer, two of whom also underwent 68Ga-PSMA-617 imaging for direct comparison. Semiquantitative assessment of physiologic biodistribution and tumor burden was conducted, and the radiation dosimetry of 68Ga-PSMA-33 was estimated. Results: 68Ga-PSMA-33 was efficiently prepared with a labeling yield of 77.5 ± 7.23%, radiochemical purity exceeding 99%, and specific activity of 45.28 ± 6.37 GBq/μmol. The labeled compound demonstrated a high affinity for PSMA (0.103 ± 0.03 nM), along with high hydrophilicity (Log P = −2.84 ± 0.13). Micro-PET/CT imaging revealed rapid clearance and prominent tumor uptake of the tracer, achieving a significantly higher tumor-to-muscle ratio than 68Ga-PSMA-617 (88.85 ± 8.39 vs 30.18 ± 3.39, p < 0.001) at 4 h postinjection. A total of nearly 400 tumor lesions were identified in PET/CT imaging across the 7 patients with prostate cancer. The mean SUVmax values of primary tumors, lymph node metastases, liver metastases, and bone metastases were 22.24 ± 4.77, 10.48 ± 2.16, 21.76 ± 3.82, and 30.25 ± 2.80 at 1 h postinjection, respectively. Clinical 68Ga-PSMA-33 PET/CT studies further confirmed its favorable biodistribution and kinetics, exhibiting a significantly higher tumor-to-muscle ratio than 68Ga-PSMA-617 at 3 h postinjection in both lymph node metastases (23.64 ± 6.68 vs 17.47 ± 7.53, p < 0.01) and bone metastases (83.33 ± 18.80 vs 61.63 ± 13.26, p < 0.001). The radiation dose of 68Ga-PSMA-33 was within an acceptable range, with an effective dose of (7.38 ± 1.44) × 10–3 mSv/MBq. The kidneys were the critical organ, receiving the highest absorbed dose of (7.35 ± 2.64) × 10–2 mGy/MBq. Conclusion: 68Ga-PSMA-33 demonstrated comparable tumor uptake while providing a higher tumor-to-background ratio and lower radiation exposure than 68Ga-PSMA-617, making it a promising novel tracer for prostate cancer diagnosis.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: