Key result
Isolated aortic valve replacement for aortic stenosis resulted in a 10-year survival of 63%, with left ventricular failure and age identified as independent predictors.
Cohort (n=122)
Left ventricular failure, age, pulse pressure, and cardio-thoracic index are independent predictors of long-term survival after aortic valve replacement for aortic stenosis.
Answers are grounded in this paper and cite their sources.
Supports preoperative risk stratification by LV function and age in aortic stenosis; leaves open applicability to current prostheses and techniques.
A total of 122 patients (mean age: 55 years, range 20-75 years) were alive 30 days after isolated aortic valve replacement (AVR) performed in 1965-73 for aortic valve stenosis (AS). Cold chemical Bretschneider cardioplegia was used in all operations. The maximum follow-up was 17 years, mean 9 years. The 10-year cumulative survival +/- SE was 63 +/- 4%. Twenty-one preoperative clinical, invasive and valve-related variables were entered into a Cox regression analysis. Variables with independent predictive value regarding long-term survival were: Left ventricular failure (regression coefficient: b = 1.078, p less than 0.0002), age (b = 0.749, p less than 0.009), pulse pressure (b = -0.663, p less than 0.02) and cardio-thoracic index (CTI) (b = 0.603, p less than 0.04). Based on these variables, a prognostic index with 16 different risk groups was made. In the "best" group (n = 8), the observed 10-year survival +/- SE was 88 +/- 11%, compared to 13 +/- 12% for the "worst" group (n = 8). Multivariate analysis of complication-free survival showed that the total valve-related complication-rate (VRC) (4.2/100 pat.-yrs) was influenced by valve type (Starr-Edwards ball valves, n = 118, versus Lillehei-Kaster and Smeelof-Cutter valves, n = 4) and CTI. The valve- and heart-related events (VRC together with late myocardial infarctions and pacemaker implantations, 6.5/100 pat.-yrs) depended on CTI and previous myocardial infarction. No predictors of thromboembolism (1.6/100 pat.-yrs) or coumarin-related hemorrhage (1.8/100 pat.-yrs) could be identified.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Lund et al. (1987) conducted a cohort in Aortic valve stenosis (n=122). Isolated aortic valve replacement was evaluated on 10-year cumulative survival. Isolated aortic valve replacement for aortic stenosis resulted in a 10-year survival of 63%, with left ventricular failure and age identified as independent predictors.
Synapse has enriched 10 related papers. Consider them for comparative context: