Key result
Lower deceleration or higher acceleration capacity predicts greater AF-free survival six months post-ablation.
Why the study?
Do low deceleration capacity and high acceleration capacity predict a higher atrial fibrillation-free rate in patients with drug-refractory paroxysmal atrial fibrillation undergoing circumferential pulmonary vein isolation?
Cohort (n=154)
Single-blind
No
Do low deceleration capacity and high acceleration capacity predict a higher atrial fibrillation-free rate in patients with drug-refractory paroxysmal atrial fibrillation undergoing circumferential pulmonary vein isolation?
High acceleration capacity (≥ -5.1 ms) and low deceleration capacity (< 4.8 ms) are associated with a significantly higher atrial fibrillation-free survival rate after circumferential pulmonary vein isolation.
Answers are grounded in this paper and cite their sources.
DC <4.8 ms or AC ≥-5.1 ms was associated with higher AF-free rates post-ablation; hypothesis-generating for risk stratification, needs prospective validation.
How deceleration capacity (DC) and acceleration capacity (AC) of heart rate associated with atrial fibrillation (AF) and ablation is still not clear. The dynamic changes of AC, DC and conventional heart rate variability (HRV) parameters were characterized in 154 subjects before circumferential pulmonary veins isolation (CPVI) and three days, 3 months and 6 months after CPVI. The DCs of the recurrent group decreased significantly at each time point after CPVI; the DCs of the recurrence-free group before CPVI and three days, 3 months and 6 months after CPVI were 7.06 ± 1.77, 3.79 ± 1.18, 4.22 ± 1.96 and 3.97 ± 0.98 ms respectively, which also decreased significantly at each time point and were significantly lower than these of recurrent group. Conversely, the AC of recurrent and recurrence-free groups increased significantly at each time point after CPVI; the ACs of recurrence-fee group were significantly higher than these of recurrent group at each time point. No stable difference trend of HRV parameters was found between two groups. Further Kaplan-Meier analysis showed that DC < 4.8 ms or AC ≥ -5.1 ms displayed significant higher recurrence-free rates. In conclusion, high AC and low DC imply higher AF-free rate after ablation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2018) conducted a cohort in Drug-resistant paroxysmal atrial fibrillation (n=154). Circumferential pulmonary vein isolation (CPVI) vs. High deceleration capacity (≥ 4.8 ms) or low acceleration capacity (< -5.1 ms) was evaluated on Atrial fibrillation recurrence-free survival at 6 months (p=<0.001). Patients with a deceleration capacity < 4.8 ms or acceleration capacity ≥ -5.1 ms had significantly higher atrial fibrillation recurrence-free rates 6 months after catheter ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: