Key result
4DCT fractal dimension analysis identifies a ~66% lower peak systolic percentage change in abnormal subjects.
Why the study?
To develop a method leveraging the high fidelity of CT to quantify regional left ventricular function using topography variation of the endocardium as a surrogate measure of strain.
Does fractal dimension analysis of the left ventricular endocardium from 4DCT images accurately quantify regional left ventricular function and differentiate normal from abnormal subjects?
Observational (n=20)
Does fractal dimension analysis of the left ventricular endocardium from 4DCT images accurately quantify regional left ventricular function and differentiate normal from abnormal subjects?
Fractal dimension analysis of the left ventricular endocardium from 4DCT images provides a contour-free method to quantify regional LV function and distinguish between normal and abnormal subjects.
Answers are grounded in this paper and cite their sources.
May support contour-free regional LV assessment on 4DCT; leaves open prospective validation before clinical adoption.
We present a method to leverage the high fidelity of CT to quantify regional left ventricular function using topography variation of the endocardium as a surrogate measure of strain. 4DCT images of 10 normal and 10 abnormal subjects, acquired with standard clinical protocols, were used. The topography of the endocardium was characterized by its regional values of fractal dimension (F D ), computed using a box-counting algorithm developed in-house. The average F D in each of the 16 American Heart Association segments was calculated for each subject as a function of time over the cardiac cycle. The normal subjects showed a peak systolic percentage change in F D of 5.9% ± 2% in all free-wall segments, while the abnormal cohort experienced a change of 2% ± 1.2% (p < 0.00001). Septal segments, being smooth, did not undergo large changes in F D . Additionally, a principal component analysis was performed on the temporal profiles of F D to highlight the possibility for unsupervised classification of normal and abnormal function. The method developed is free from manual contouring and does not require any feature tracking or registration algorithms. The F D values in the free wall segments correlated well with radial strain and with endocardial regional shortening measurements.
No takes yet. Share an insight, caveat, or question.
Manohar et al. (2019) conducted an observational in Left ventricular dysfunction (n=20). 4DCT fractal dimension (FD) analysis vs. Normal subjects was evaluated on Peak systolic percentage change in FD in free-wall segments (p=<0.00001). Fractal dimension analysis of 4DCT images demonstrated a peak systolic percentage change of 5.9% in normal subjects compared to 2% in abnormal subjects.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: