Key result
Standard CMR cine measures of LV mechanical dyssynchrony demonstrate good inter-study reproducibility.
Why the study?
Are left ventricular mechanical dyssynchrony measures derived from standard CMR cine images reproducible across repeated exams in healthy volunteers?
Observational (n=16)
No
Are left ventricular mechanical dyssynchrony measures derived from standard CMR cine images reproducible across repeated exams in healthy volunteers?
Uniformity ratio estimates and 4D-volume-SDI derived from standard CMR cine images demonstrate good inter-study reproducibility, suggesting potential clinical utility for assessing LV mechanical dyssynchrony.
Answers are grounded in this paper and cite their sources.
Supports CMR dyssynchrony research; leaves open clinical utility pending patient validation.
OBJECTIVES: To determine the inter-study reproducibility of left ventricular (LV) mechanical dyssynchrony measures based on standard cardiovascular magnetic resonance (CMR) cine images. DESIGN: Steady-state free precession (SSFP) LV short-axis stacks and three long-axes were acquired on the same day at three time points. Circumferential strain systolic dyssynchrony indexes (SDI), area-SDI as well as circumferential and radial uniformity ratio estimates (CURE and RURE, respectively) were derived from CMR myocardial feature-tracking (CMR-FT) based on the tracking of three SSFP short-axis planes. Furthermore, 4D-LV-analysis based on SSFP short-axis stacks and longitudinal planes was performed to quantify 4D-volume-SDI. SETTING: A single-centre London teaching hospital. PARTICIPANTS: 16 healthy volunteers. MAIN OUTCOME MEASURES: Inter-study reproducibility between the repeated exams. RESULTS: CURE and RURE as well as 4D-volume-SDI showed good inter-study reproducibility (coefficient of variation [CoV] 6.4%-12.9%). Circumferential strain and area-SDI showed higher variability between the repeated measurements (CoV 24.9%-37.5%). Uniformity ratio estimates showed the lowest inter-study variability (CoV 6.4%-8.5%). CONCLUSIONS: Derivation of LV mechanical dyssynchrony measures from standard cine images is feasible using CMR-FT and 4D-LV-analysis tools. Uniformity ratio estimates and 4D-volume-SDI showed good inter-study reproducibility. Their clinical value should next be explored in patients who potentially benefit from cardiac resynchronization therapy.
No takes yet. Share an insight, caveat, or question.
Kowallick et al. (2017) conducted an observational in Healthy volunteers (n=16). Cardiovascular magnetic resonance (CMR) cine images for LV mechanical dyssynchrony vs. Repeated exams was evaluated on Inter-study reproducibility between the repeated exams. Left ventricular mechanical dyssynchrony measures using uniformity ratio estimates and 4D-volume-SDI from standard CMR cine images showed good inter-study reproducibility.