Key result
Single heartbeat cardiac tagging using EPI-SSFP and TSENSE achieved temporal resolutions of 35-52 ms and spatial resolutions of 1.32-2.65 mm, enabling evaluation of transient cardiac phenomena.
Why the study?
Does single heartbeat cardiac tagging improve the evaluation of transient cardiac phenomena compared to heartbeat-interleaved acquisition?
Does single heartbeat cardiac tagging improve the evaluation of transient cardiac phenomena compared to heartbeat-interleaved acquisition?
Single heartbeat cardiac tagging using EPI-SSFP and TSENSE allows for high-resolution evaluation of transient cardiac phenomena without the temporal blurring associated with segmented imaging.
May enable single-beat strain assessment during transient events; leaves open validation against segmented tagging in clinical cohorts.
Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heartbeat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and inter-heartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.
No takes yet. Share an insight, caveat, or question.
Herzka et al. (2005) studied Transient cardiac phenomena. Single heartbeat cardiac tagging (EPI-SSFP and TSENSE) vs. Heartbeat-interleaved acquisition was evaluated on Temporal and spatial resolution, local apparent strains, and ventricular areas. Single heartbeat cardiac tagging using EPI-SSFP and TSENSE achieved temporal resolutions of 35-52 ms and spatial resolutions of 1.32-2.65 mm, enabling evaluation of transient cardiac phenomena.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: