Key result
REPAIRit 3D LGE improves nulling and reduces ghosting, but arrhythmias link to ~43% lower blood SNR.
Why the study?
Does the REPAIRit 3D LGE sequence improve image quality in arrhythmia patients compared to standard LGE?
Observational (n=14)
Does the REPAIRit 3D LGE sequence improve image quality in arrhythmia patients compared to standard LGE?
The REPAIRit 3D LGE sequence improves myocardial nulling and reduces ghosting artifacts, enhancing image quality for patients with arrhythmias.
Answers are grounded in this paper and cite their sources.
May improve LGE image quality in arrhythmia patients; hypothesis-generating and requires prospective validation before practice change.
BACKGROUND: Cardiac 3D navigator-gated late gadolinium enhancement (LGE) imaging is important for assessment of left atrial fibrosis, but the image quality is often degraded due to arrhythmia. PURPOSE: To investigate a novel 3D LGE sequence with improved myocardial nulling and reduced ghosting artifacts during arrhythmia. STUDY TYPE: Prospective. POPULATION: Arrhythmia patients (n = 14). SEQUENCE: , REPAIRit automatically calculates the optimal inversion time (TI) based on Bloch equations. ASSESSMENT: REPAIRit LGE and the standard LGE were compared with simulations, phantom imaging, and patient studies. Patient images were assessed quantitatively, based on ghost-to-noise ratio (GNR), blood signal-to-noise ratio (SNRb), myocardial signal-to-noise ratio (SNRm), and blood-to-myocardium contrast-to-noise ratio (CNR), and qualitatively on a 4-point scale. Patients were subgrouped based on the presence of arrhythmia to assess the image quality difference. STATISTICAL TESTS: The two LGE sequences were compared by Student's t-test and Wilcoxon signed-rank test. The two patient-subgroups were compared using Welch's t-test and Wilcoxon rank-sum test. RESULTS: s (318 ± 55 msec vs. 316 ± 27 msec, P = 0.96), and significantly lower blood SNR (5.2 ± 1.8 vs. 9.2 ± 3.0, P = 0.01) and significantly worse image quality (P = 0.01 for REPAIRit and P = 0.03 for standard). DATA CONCLUSION: REPAIRit improves myocardial nulling and reduces ghosting artifacts of 3D LGE under arrhythmia. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:688-699.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2018) conducted an observational in Arrhythmia (n=14). REPAIRit 3D LGE sequence vs. Standard LGE sequence was evaluated on Image quality, ghost-to-noise ratio, blood and myocardial signal-to-noise ratio, and contrast-to-noise ratio. The REPAIRit 3D LGE sequence improved myocardial nulling and reduced ghosting artifacts, though arrhythmia presence was still associated with lower blood SNR.
Synapse has enriched 10 related papers. Consider them for comparative context: