Shielding effectiveness relates to the ability of a material to reduce the transmission of propagating fields in order to electromagnetically isolate one region from another. Because the shielding capability of a complex material is difficult to predict, it often must be measured. A number of approaches to simulating far-field source are studied, including the use of coaxial transmission-line holders and a time-domain system. In each case, the system frequency range, test sample requirements, test field type, dynamic range, measurement time required, and analytical background are considered. Data taken on a common set of materials are presented.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Wilson et al. (1988) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: