Key result
Adding T-wave heterogeneity to regadenoson MPI is linked to ~7-fold greater detection of flow-limiting lesions.
Why the study?
It was unknown whether incorporating electrocardiographic interlead T-wave heterogeneity with myocardial perfusion imaging during pharmacologic stress improves the detection of flow-limiting lesions.
Does incorporating electrocardiographic interlead T-wave heterogeneity with myocardial perfusion imaging during regadenoson stress testing improve the detection of flow-limiting coronary lesions?
Observational (n=103)
No
Does incorporating electrocardiographic interlead T-wave heterogeneity with myocardial perfusion imaging during regadenoson stress testing improve the detection of flow-limiting coronary lesions?
Effect estimate: OR 6.8 (95% CI 2.2-21.4)
p-value: p=0.001
Combining T-wave heterogeneity analysis with myocardial perfusion imaging during regadenoson stress testing significantly improves the diagnostic accuracy for detecting flow-limiting coronary lesions by reducing false positives.
AIMS: We analysed whether incorporating electrocardiographic interlead T-wave heterogeneity (TWH) with myocardial perfusion imaging (MPI) during pharmacologic stress improves detection of flow-limiting lesions (FLL). METHODS AND RESULTS: Medical records of all 103 patients at our institution who underwent stress testing with regadenoson (0.4 mg IV bolus) within 3 months of coronary angiography from September 2017 to March 2019 were studied. Cases (N = 59) had angiographically significant FLL (≥50% of left main or ≥70% of other epicardial coronary arteries ≥2 mm in diameter); controls (N = 44) were normal or had non-FLL. TWH, i.e., interlead splay of T waves, was assessed from precordial leads V4-6 by second central moment analysis. Maximum TWHV4-6 levels during regadenoson stress were 68% higher in cases than in controls (P < 0.0001). TWHV4-6 generated areas under the receiver-operating characteristic (ROC) curve of 0.79 in men (P < 0.0001) and 0.71 in women (P = 0.007). In men, the ROC-guided 54-µV TWHV4-6 cut-point for FLL produced adjusted odds of 7.3 [95% confidence interval (CI): 1.3-41.5, P = 0.03], 79% sensitivity, and 78% specificity. In women, the ROC-guided 35-µV TWHV4-6 cut-point produced adjusted odds of 4.5 (95% CI: 1.1-18.9, P = 0.04), 84% sensitivity, and 52% specificity. Adding TWHV4-6 to MPI determinations reduced false-positive results by 70%, more than doubled true-negative results, and improved adjusted odds ratio to 6.8 (95% CI: 2.2-21.4, P = 0.001) with specificity of 78% in men and 86% in women. CONCLUSION: This observational study is the first to demonstrate the benefit of combining TWHV4-6 with MPI to enhance FLL detection during MPI with regadenoson in both men and women.
No takes yet. Share an insight, caveat, or question.
Silva et al. (2020) conducted an observational in Coronary stenosis / Flow-limiting lesions (n=103). T-wave heterogeneity (TWH) combined with myocardial perfusion imaging (MPI) vs. MPI alone / Controls without FLL was evaluated on Detection of flow-limiting lesions (FLL) (OR 6.8, 95% CI 2.2-21.4, p=0.001). Adding T-wave heterogeneity to myocardial perfusion imaging during regadenoson stress improved the detection of flow-limiting lesions (adjusted OR 6.8; 95% CI 2.2-21.4; P=0.001).