Key result
Ablation index protocol during PVI is linked to ~41% less myocardial injury versus standard applications.
Why the study?
Whether the ablation index protocol reduces myocardial injury during catheter ablation compared to standard protocols was unknown.
Does the Ablation Index (AI) protocol reduce myocardial injury compared to standard dragging technique during pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
Cohort (n=24)
Does the Ablation Index (AI) protocol reduce myocardial injury compared to standard dragging technique during pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
The use of the Ablation Index protocol during pulmonary vein isolation for paroxysmal atrial fibrillation significantly reduces myocardial injury compared to the standard dragging technique.
Answers are grounded in this paper and cite their sources.
AI protocol was associated with less myocardial injury during PVI; hypothesis-generating and requires randomized outcome trials before practice change.
Background New protocols of pulmonary veins isolation (PVI) result in easier and more efficient procedure performance. Ablation index (AI) is the novel tool which helps to achieve transmural lesions during catheter ablation. However, benefit of this protocol in the reduction of myocardial injury is still not known. Purpose The aim of the study was to compare myocardial injury during catheter ablation using standard and AI protocol. Methods To the analysis we included 24 patients with paroxysmal atrial fibrillation, who underwent radiofrequency catheter PVI using CARTO system (Biosense Webster, Inc). In all patients cardiac troponin I (cTnI) levels were assessed before and 24 hours after the procedure. In 12 patients PVI was performed using continuous applications (dragging technique) and in 12 patients during PVI ablation AI protocol was implemented. To unify analyzed groups, we excluded patients with additional ablation lines (including line separating ipsilateral pulmonary veins). Results In analyzed group mean age was 59.3 ± 7.7 years and 18 (75%) patients were male. There were no differences in the clinical characteristic between both subgroups. Trend in shorter total x‐ray time was observed in AI group compared with dragging group (8.6 ± 5.4 vs. 5.3 ± 3.2 min.; P = .093) with no differences in total procedure time (146.3 ± 28.9 vs. 153.2 ± 37.1 min.; P = .616). Twenty‐four hours after the PVI procedure cTnI levels were significantly lower in AI group than in dragging group (1.984 ± 0.644 vs. 3.369 ± 1.818 ng/mL; P = .026), with no difference in mean baseline cTnI levels (0.004 ± 0.006 vs. 0.015 ± 0.032 ng/mL; P = .304). Conclusion Presented study revealed that compared with standard, continuous applications, AI protocol implementation results in reduction of myocardial injury during catheter PVI in patients with paroxysmal atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Peller et al. (2020) conducted a cohort in paroxysmal atrial fibrillation (n=24). Ablation index (AI) protocol vs. Standard continuous applications (dragging technique) was evaluated on Cardiac troponin I (cTnI) levels 24 hours after the procedure (p=0.026). Ablation index protocol implementation during pulmonary vein isolation reduced myocardial injury compared with standard continuous applications.
Synapse has enriched 10 related papers. Consider them for comparative context: