Key result
Higher tip apex distance averaging ~37 mm is linked to dynamic hip screw cut-out.
Why the study?
Despite DHS fixation being a common option for proximal femur fractures, the failure rate is high if tip apex distance is neglected.
Does Tip Apex Distance affect the outcome of dynamic hip screw fixation in intertrochanteric fractures?
Observational (n=26)
No
Does Tip Apex Distance affect the outcome of dynamic hip screw fixation in intertrochanteric fractures?
The study aims to evaluate the impact of tip apex distance on the outcomes of dynamic hip screw fixation for intertrochanteric fractures.
Answers are grounded in this paper and cite their sources.
Higher tip-apex distance associated with cut-out; leaves open whether TAD optimization improves dynamic hip screw outcomes.
Fractures of proximal femur account for 30% of all hospitalization for fractures. Most fractures occur in the elderly usually in association with osteoporosis and as a result of only moderate or minimal trauma. Literature suggests, Despite being a great option, the failure chance of DHS fixation is high if negligence made to Tip Apex Distance. This study is to assess the outcome of DHS with regards to Tip Apex distance.
No takes yet. Share an insight, caveat, or question.
Mohan et al. (2019) conducted an observational in Intertrochanteric fractures (n=26). Dynamic Hip Screw (DHS) was evaluated on Screw cut out. In patients with intertrochanteric fractures treated with a dynamic hip screw, screw cut-out occurred in cases with an average tip apex distance of 36.5 mm compared to 20.6 mm in successful fixations.
Synapse has enriched 10 related papers. Consider them for comparative context: