PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 5, 2005Journal of Hypertension162 citations

Efficacy of a home blood pressure monitoring programme on therapeutic compliance in hypertension: the EAPACUM–HTA study

View Full Paper
ECE. Márquez ContrerasNCNieves Martell ClarosVGVicente Gil-Guillén

Key Result

A home blood pressure monitoring programme significantly improved therapeutic compliance compared to standard care (92% vs 74%; P=0.0001) in patients with mild-to-moderate hypertension.

Study Design

Type

RCT (n=250)

Randomization

Randomly selected

Multicenter

Yes

Structured PICO

Does a home blood pressure monitoring programme improve therapeutic compliance in patients with mild-to-moderate hypertension?

P
Population
250 patients with newly diagnosed or uncontrolled mild-to-moderate hypertension across 40 primary care centres in Spain.
I
Intervention
Home blood pressure measurement (HBPM) programme using an OMRON monitor at home.
C
Comparator
Standard health intervention.
O
Outcome
Therapeutic compliance (defined as drug consumption of 80-110% measured by monitoring events medication system [MEMS]) at 6 months.surrogate

A home blood pressure monitoring program significantly improves medication compliance in patients with mild-to-moderate hypertension.

Main Result

Absolute Event Rate: 92% vs 74%

p-value: p=0.0001

Abstract

OBJECTIVE: To evaluate the efficacy of a programme of home blood pressure measurement (HBPM) on therapeutic compliance in mild-to-moderate hypertension. DESIGN: A prospective controlled multicentre clinical trial. SETTING: Forty primary care centres in Spain, with a duration of 6 months. PATIENTS: A total of 250 patients with newly diagnosed or uncontrolled hypertension were included. INTERVENTIONS: The patients were randomly selected and distributed in two groups: (1) the control group (CG) who received standard health intervention; (2) the intervention group (IG): the patients in this group received an OMRON in their homes for a programme of HBPM. MAIN OUTCOME MEASURE: Four visits were scheduled, for the measurement of blood pressure (BP). They were provided with an electronic monitor for measuring compliance (monitoring events medication system; MEMS). Therapeutic compliance was defined as a drug consumption of 80-110%. A number of variables were calculated using the MEMS. The mean BP were calculated and the percentage of controlled patients. RESULTS: A total of 200 patients completed the study (100 in each group). Compliance was observed in 74 and 92%, respectively, in the CG and IG 95% confidence interval (CI) 63.9-84.1 and 86.7-97.3; P = 0.0001, the mean percentage compliances were 87.6 and 93.5% (95% CI 81.2-94 and 80.7-98.3; P = 0.0001), the percentages of correct days were 83.6 and 89.4%, the percentages of subjects who took the medication at the prescribed time were 79.89 and 88.06%, and the levels of therapeutic cover were 86.7 and 93.1%. The number needed to treat to avoid one case of non-compliance was 5.6 patients. The differences in the mean decreases in BP were significant for diastolic BP, with a greater decrease observed in the IG. CONCLUSIONS: An HBPM programme using electronic monitors is effective in improving compliance in arterial hypertension, measured using the MEMS.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Contreras et al. (2005) conducted an RCT in Mild-to-moderate hypertension (n=250). Home blood pressure measurement (HBPM) programme vs. Standard health intervention was evaluated on Therapeutic compliance (drug consumption of 80-110%) (p=0.0001). A home blood pressure monitoring programme significantly improved therapeutic compliance compared to standard care (92% vs 74%; P=0.0001) in patients with mild-to-moderate hypertension.

synapsesocial.com/papers/6a093437071d6da446961239https://doi.org/10.1097/01.hjh.0000198023.53859.a2