Answers are grounded in this paper and cite their sources.
Demonstrates effective arc fault detection in photovoltaic systems, suggesting enhanced safety measures.
Series arc faults on the DC side of photovoltaic (PV) systems are a critical hazard that can trigger system fires. Conventional contact-based detection methods suffer from cumbersome installation and high retrofit cost, whereas existing non-contact approaches mostly rely on megahertz-level high-frequency sampling and therefore require expensive radio-frequency instrumentation or high-performance computing platforms. As a result, it remains difficult to simultaneously achieve strong interference immunity and real-time performance on low-cost embedded devices with limited resources. To address this engineering paradox between high-frequency sampling and constrained computational capability, this paper proposes a fully embedded, non-contact arc fault detection system based on a 12–80 kHz low-frequency sub-band selection strategy. By exploiting the physical characteristic of broadband energy elevation induced by arc faults, the proposed strategy avoids dependence on high-bandwidth hardware. Guided by this strategy, a Moebius-topology coaxial shielded loop antenna is employed as the near-field sensor, while an ultra-simplified passive analog front end is constructed directly by using the on-chip programmable gain amplifier and analog-to-digital converter of the microcontroller unit, enabling efficient signal acquisition and fast Fourier transform processing within the target sub-band. To cope with complex background noise in the low-frequency range, an environment-adaptive baseline mechanism based on exponential moving average and exponential absolute deviation is developed for dynamic decoupling. In addition, a lightweight INT8-quantized multilayer perceptron is introduced as a nonlinear auxiliary module, thereby forming a robust hybrid decision architecture with complementary rule-based and artificial intelligence components. Experimental results show that, under the tested household, laboratory, and PV-site conditions, the proposed system achieved an overall detection rate of 97%, while the remaining 3% mainly corresponded to failed ignition or non-sustained arc attempts rather than persistent false triggering during normal monitoring.
No takes yet. Share an insight, caveat, or question.
HongMing et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: