Answers are grounded in this paper and cite their sources.
Single-center study evaluates partial fluid-air exchange to improve retinal sheet delivery, suggesting surgical benefits.
Background and Objective: Subretinal therapeutics represent a growing area of research with diverse clinical applications. Inadvertent reflux of therapeutic into the vitreous after delivery represents a surgical challenge that leads to therapeutic loss. This study sought to evaluate a modified technique utilizing partial fluid-air exchange (pFAX) to reduce reflux. Materials and Methods: This single-center study included 18 eyes of nine live pigs. Human iPSC-derived retinal sheets (Sumitomo Pharma) were injected into the subretinal space utilizing pFAX. Results: Retinal sheets were successfully delivered in all eyes. Incorporating pFAX reduced intraocular turbulence and reflux by maintaining (1) stable intraocular pressure, (2) self-sealing wound closure, and (3) subretinal bleb stability. When improper delivery or reflux of sheets did occur, reaspiration and reinjection was much easier with pFAX than with a fluid-filled eye. Conclusion: Incorporating pFAX reduced reflux during subretinal injection of retinal sheets. This technique may enhance current and future applications of subretinal surgery.
No takes yet. Share an insight, caveat, or question.
Baldwin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: