To determine the validity of endogenous creatinine clearance as a measure of glomerular filtration rate in patients with renal disease 308 simultaneous determinations of inulin clearance and endogenous creatinine clearance were reviewed and analysed. The ratio of creatinine clearance/inulin clearance increased progressively with the decline in inulin clearance, while the finding of a normal endogenous creatinine clearance masked a definite but mild decrease of glomerular filtration rate in 42% of the patients and a moderate decrease of glomerular filtration rate in 23%. This indicates that with declining glomerular filtration rates the endogenous creatinine clearance progressively overestimates actual glomerular filtration rates. Hence a single determination of creatinine clearance can be misleading as a screening measurement of glomerular filtration rate.
No takes yet. Share an insight, caveat, or question.
Kim et al. (1969) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: