Answers are grounded in this paper and cite their sources.
We present an intensity-ratio error-compensation method to decrease the measurement error caused by projector gamma nonlinearity and image defocus in triangular-pattern phase-shifting profilometry. The intensity-ratio measurement error is first determined by simulating the measurement with the triangular-pattern phase-shifting method with ideal and real captured triangular-pattern images based on the ideal and real gamma nonlinearity functions. A lookup table that stores the intensity-ratio measurement error corresponding to the measured intensity ratio is constructed and used for intensity-ratio error compensation. Experiments demonstrated that the intensity-ratio error compensation method significantly reduced the measurement error in the triangular-pattern phase-shifting method by 28.5%.
No takes yet. Share an insight, caveat, or question.
Jia et al. (2007) studied this question.