Key result
Distal radial access shows no difference in 30-day hand function versus proximal access.
Why the study?
Proximal radial artery access can jeopardize artery use due to occlusion, whereas distal radial artery access preserves it but has unknown safety and effects on hand function.
Does distal radial artery access improve hand function and safety compared to proximal radial artery access in patients undergoing cardiac catheterization?
RCT (n=300)
1:1
No
Does distal radial artery access improve hand function and safety compared to proximal radial artery access in patients undergoing cardiac catheterization?
Distal radial artery access is a safe strategy for cardiac catheterization with no increased risk of hand dysfunction at 30 days compared to proximal access.
Distal radial access preserves hand function equivalently; supports its routine use as a safe alternative to proximal access.
Background Proximal radial artery (pRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (dRA) access in the anatomical snuffbox preserves the radial artery, but safety and potential detrimental effects on hand function are unknown. Methods and Results In the DIPRA (Distal Versus Proximal Radial Artery Access for Cardiac Catheterization and Intervention) study, a single‐center trial, 300 patients were randomized 1:1 to cardiac catheterization through dRA or pRA. The primary end point of change in hand function from baseline to 30 days was a composite of the QuickDASH (Quick Disabilities of the Arm, Shoulder and Hand) questionnaire, hand‐grip test, and thumb forefinger pinch test. Secondary end points included access feasibility and complications; 254 of 300 patients completed follow‐up at 30 days; of these, 128 were randomized to dRA and 126 to pRA with balanced demographic and procedural characteristics. Both groups had similar rates of access site bleeding (dRA 0% versus pRA 1.4%; P =0.25). Six patients with dRA failed access compared with 2 patients with pRA. Radial artery occlusion occurred in 2 pRA versus none in dRA. There were no significant differences in change in hand function, median hand‐grip (dRA 0 [−3.2, 3.3] versus pRA 0.7 [−2.3, 3.3] kg; P =0.21), pinch‐grip (dRA −0.3 [−1.2, 0.5] versus pRA 0 [−0.9, 0.9] kg; P =0.09), and QuickDASH (dRA 0 [−4.6, 2.3] versus pRA 0 [−4.6, 2.3] points, P =0.96). There was no significant difference in the composite of hand function between pRA and dRA. Conclusions dRA is a safe strategy for cardiac catheterization with a low complication rate. Compared with pRA, there is no increased risk of hand dysfunction at 30 days. Registration URL: https://www.ClinicalTrials.gov . Unique identifier: NCT04318990.
No takes yet. Share an insight, caveat, or question.
Al‐Azizi et al. (2023) conducted an RCT in cardiac catheterization (n=300). Distal radial artery (dRA) access vs. Proximal radial artery (pRA) access was evaluated on change in hand function from baseline to 30 days (composite of QuickDASH questionnaire, hand-grip test, and thumb forefinger pinch test). Distal radial artery access for cardiac catheterization showed no significant difference in hand function at 30 days compared with proximal access (median hand-grip change 0 vs 0.7 kg; P=0.21).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: