Why the study?
Patients with ESKD are prone to bloodstream infections that may increase CIED infection risk, but incidence, risk predictors, management, and long-term outcomes required assessment.
Does early lead extraction improve survival in ESKD patients who develop CIED infections?
Does early lead extraction improve survival in ESKD patients who develop CIED infections?
In patients with ESKD, CIED infections are frequent and carry high mortality, but early lead extraction is associated with improved survival despite being underutilized.
Extraction associated with lower mortality in ESKD with CIED infection; leaves open causal benefit pending randomized trials.
BACKGROUND: End-stage kidney disease (ESKD) patients are prone to bloodstream infections that may result in a higher risk of cardiac implantable electronic device (CIED) infections. OBJECTIVE: The objective of this study was to assess the incidence, risk predictors, management strategies, and long-term outcomes of CIED infections in ESKD patients undergoing de novo CIED implantation. METHODS: This is a retrospective study using the United States Renal Data System. ESKD patients with de novo CIED implantation between January 1, 2006, and September 30, 2014, were included. Patients were observed until death, kidney transplantation, end of Medicare coverage, or September 30, 2015, to assess incidence of CIED infection. Management approach was determined from procedure codes for lead extraction within 60 days of CIED infection diagnosis. Patients with CIED infection were observed until December 31, 2019, to assess long-term outcomes. RESULTS: Of 15,515 ESKD patients undergoing de novo CIED implantation, incidence of CIED infection was 4.8% during a median follow-up of 1.3 years. The presence of a defibrillator (adjusted hazard ratio [aHR], 1.48), higher body mass index (aHR, 1.01), and younger age (aHR, 0.96) were independent risk factors for CIED infection. Lead extraction occurred in only 50.71% of patients by 60 days. After propensity score matching, the 3-year mortality was higher in those who did not undergo lead extraction compared with those who did (80.3% vs 72.3%) and time to mortality was shorter (0.3 vs 0.6 year). Only 13.8% of patients underwent reimplantation with a new CIED after lead extraction. CONCLUSION: CIED infections occur frequently in ESKD patients and are associated with a high mortality. Early lead extraction is not performed routinely but is associated with improved survival.
No takes yet. Share an insight, caveat, or question.
Jiwani et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: