Answers are grounded in this paper and cite their sources.
10-kHz hydroxyl radical (OH) two-color planar laser-induced fluorescence (TC-PLIF) thermometry was demonstrated with a single burst-mode optical parametric oscillator (OPO) and a single camera. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8\; nm. The two pulse trains are colinear with 3 µs time interval between the pulse pairs. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 and 285.67 nm to excite the Q₂(12) and P₁(8) OH transitions. PLIF images were collected from each of the two excitation transitions, and intensity ratios from the images were used to determine local temperatures. The development of fast, dual-wavelength switching, burst-mode OPO technology significantly reduces the experimental complexity of the high-speed TC-PLIF thermometry and simplifies its implementation in harsh combustion and flow test facilities.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: