Key result
Haemodynamic treatment in acute circulatory failure is linked to ~22% reduced t-IVT and improved VA coupling.
Why the study?
Validation of electromechanical coupling parameters in critically ill patients is ongoing, and a unifying link between ventriculo-arterial coupling and electromechanical coupling may exist in acute circulatory failure.
Does haemodynamic treatment improve electromechanical dyssynchrony and ventriculo-arterial coupling in adult patients with acute circulatory failure?
Observational (n=54)
No
Does haemodynamic treatment improve electromechanical dyssynchrony and ventriculo-arterial coupling in adult patients with acute circulatory failure?
p-value: p=0.001
Haemodynamic treatment in acute circulatory failure improves cardiac electromechanical coupling and ventriculo-arterial coupling, specifically in patients with baseline dyssynchrony.
May support haemodynamic optimization in dyssynchronous acute failure; hypothesis-generating and requires randomized confirmation.
Introduction Two parallel paradigms of cardiovascular efficiency and haemodynamic optimisation coexist in haemodynamic research. Targeting ventriculo-arterial (VA) coupling [i.e., the ratio between arterial and ventricular elastance (E V )] and electromechanical coupling are two promising approaches in acute circulatory failure. However, validation of the parameters of electromechanical coupling in critically ill patients is ongoing. Furthermore, a unifying link between VA and electromechanical coupling may exist, as E V is correlated with different times of the cardiac cycle. Materials and Methods This study was a retrospective analysis of a prospectively collected observational database from one tertiary center ICU. We analyzed the relationship between electromechanical dyssynchrony and acute circulatory failure hemodynamics before and after treatment (i.e., fluid expansion, dobutamine, or norepinephrine infusion). The relationship between electromechanical coupling and VA coupling was also investigated. Adult patients with haemodynamic instability were included. Haemodynamic parameters, including arterial pressure, cardiac index, VA coupling, stroke work index/pressure–volume area (SWI/PVA), t-IVT, and Tei's index, were collected before and after treatment. A t-IVT of >12 s/min was classified as intraventricular dyssynchrony. Results We included 54 patients; 39 (72.2%) were classified as having intraventricular dyssynchrony at baseline. These patients with baseline dyssynchrony showed a statistically significant amelioration of t-IVT (from 18 ± 4 s to 14 ± 6 s, p = 0.001), left ventricular E V [from 1.1 (0.72–1.52) to 1.33 (0.84–1.67) mmHg mL −1 , p = 0.001], VA coupling [from 2 (1.67–2.59) to 1.80 (1.40–2.21), p = 0.001], and SWI/PVA [from 0.58 (0.49–0.65) to 0.64 (0.51–0.68), p = 0.007]. Patients without baseline dyssynchrony showed no statistically significant results. The improvement in VA coupling was mediated by an amelioration of E V . All patients improved their arterial pressure and cardiac index with treatment. The haemodynamic treatment group exhibited no effect on changing t-IVT. Conclusion Acute circulatory failure is associated with electromechanical dyssynchrony. Cardiac electromechanical coupling was improved by haemodynamic treatment only if altered at baseline. The improvement of cardiac electromechanical coupling was associated with the improvement of markers of cardiocirculatory efficacy and efficiency (i.e., SWI/PVA and VA coupling). This study was the first to demonstrate a possible link between cardiac electromechanical coupling and VA coupling in patients with acute circulatory failure.
No takes yet. Share an insight, caveat, or question.
Andrei et al. (2022) conducted an observational in Acute circulatory failure (n=54). Haemodynamic treatment (fluid expansion, dobutamine, or norepinephrine infusion) vs. Pre-treatment baseline was evaluated on Change in electromechanical dyssynchrony (t-IVT) and ventriculo-arterial (VA) coupling (p=0.001). Haemodynamic treatment in patients with acute circulatory failure and baseline dyssynchrony significantly improved t-IVT (from 18 to 14 s/min, p=0.001) and VA coupling (from 2.0 to 1.8, p=0.001).