Key result
Machine learning using cuff pressure and PWV estimates aSBP and CO with under ~8% error.
Why the study?
Cardiac and aortic characteristics are crucial for cardiovascular disease detection, but noninvasive estimation of aortic hemodynamics and cardiac contractility remains challenging.
Can machine learning models accurately estimate aortic hemodynamics and cardiac contractility from noninvasive measurements?
Can machine learning models accurately estimate aortic hemodynamics and cardiac contractility from noninvasive measurements?
Machine learning models can accurately estimate aortic systolic pressure and cardiac output from noninvasive pressure measurements, and end-systolic elastance when ejection fraction is added.
May support noninvasive aortic hemodynamic estimation in research; leaves open prospective clinical validation before adoption.
Cardiac and aortic characteristics are crucial for cardiovascular disease detection. However, noninvasive estimation of aortic hemodynamics and cardiac contractility is still challenging. This paper investigated the potential of estimating aortic systolic pressure (aSBP), cardiac output (CO), and end-systolic elastance (E es ) from cuff-pressure and pulse wave velocity (PWV) using regression analysis. The importance of incorporating ejection fraction (EF) as additional input for estimating E es was also assessed. The models, including Random Forest, Support Vector Regressor, Ridge, Gradient Boosting, were trained/validated using synthetic data (n = 4,018) from an in-silico model. When cuff-pressure and PWV were used as inputs, the normalized-RMSEs/correlations for aSBP, CO, and E es (best-performing models) were 3.36 ± 0.74%/0.99, 7.60 ± 0.68%/0.96, and 16.96 ± 0.64%/0.37, respectively. Using EF as additional input for estimating E es significantly improved the predictions (7.00 ± 0.78%/0.92). Results showed that the use of noninvasive pressure measurements allows estimating aSBP and CO with acceptable accuracy. In contrast, E es cannot be predicted from pressure signals alone. Addition of the EF information greatly improves the estimated E es . Accuracy of the model-derived aSBP compared to in-vivo aSBP (n = 783) was very satisfactory (5.26 ± 2.30%/0.97). Future in-vivo evaluation of CO and E es estimations remains to be conducted. This novel methodology has potential to improve the noninvasive monitoring of aortic hemodynamics and cardiac contractility.
No takes yet. Share an insight, caveat, or question.
Bikia et al. (2020) studied Cardiovascular disease (n=4,801). Machine learning models using cuff-pressure and pulse wave velocity was evaluated on Normalized-RMSE and correlation for aortic systolic pressure (aSBP), cardiac output (CO), and end-systolic elastance (Ees). Machine learning models using cuff-pressure and pulse wave velocity accurately estimated aortic systolic pressure (RMSE 3.36%) and cardiac output (RMSE 7.60%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: