Key result
QRS notching or slurring on resting ECG demonstrated a sensitivity of 62.2% and specificity of 93.8% for detecting ischemic heart disease, outperforming abnormal Q waves in non-infarct patients.
Why the study?
Does QRS complex notching and slurring on resting ECG improve the detection of ischemic heart disease compared to abnormal Q waves in patients undergoing cardiac catheterization?
Observational (n=122)
Does QRS complex notching and slurring on resting ECG improve the detection of ischemic heart disease compared to abnormal Q waves in patients undergoing cardiac catheterization?
Absolute Event Rate: 62.2% vs 33.3%
QRS notching or slurring on a resting ECG is a moderately sensitive and highly specific marker for ischemic heart disease, particularly useful in patients without Q waves.
The resting 12-lead ECG has long been known to be an insensitive marker of underlying ischemic heart disease (IHD). The purpose of this study was to determine if QRS complex notching and slurring is of significant value as a diagnostic discriminator in the detection of IHD. The data from 205 consecutive patients coming to cardiac catheterization for evaluation of probable IHD were initially analyzed. Eighty-three patients were excluded based upon ventricular hypertrophy, bundle-branch block, lack of data, and pacemaker rhythm. The balance, 122 patients (mean age 61.7 years), were evaluated for angiographic evidence of IHD, ECG findings of QRS notching or slurring, and abnormal Q waves. The data revealed a high prevalence of QRS notching or slurring; 62.2% in those patients with IHD, double the prevalence of significant Q waves (33.3%). The two markers had an approximately equal prevalence (QRS notching or slurring 61.7% vs. Q waves 53.2%) in patients with angiographic evidence of infarction; however, in patients with less than infarct criteria for IHD, the prevalence of QRS notching or slurring was 62.8%, while only 11.6% showed abnormal Q waves. Analysis indicated that QRS notching or slurring has a sensitivity of 62.2% and a specificity of 93.8% for the detection of IHD. The study demonstrates that QRS notching or slurring is a moderately sensitive and a very specific marker of ischemic heart disease in selected patients when using the resting ECG, and is of greatest value in those patients with lesser degrees of ischemic myocardial injury where the prevalence of Q waves is low.
No takes yet. Share an insight, caveat, or question.
France et al. (1990) conducted an observational in Ischemic heart disease (n=122). QRS complex notching and slurring vs. Abnormal Q waves was evaluated on Detection of ischemic heart disease. QRS notching or slurring on resting ECG demonstrated a sensitivity of 62.2% and specificity of 93.8% for detecting ischemic heart disease, outperforming abnormal Q waves in non-infarct patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: