Answers are grounded in this paper and cite their sources.
This paper describes the design and performance of a 6-kW, full-bridge, bidirectional isolated dc-dc converter using a 20-kHz transformer for a 53.2-V, 2-kWh lithium-ion (Li-ion) battery energy storage system. The dc voltage at the high-voltage side is controlled from 305 to 355 V, as the battery voltage at the low-voltage side (LVS) varies from 50 to 59 V. The maximal efficiency of the dc-dc converter is measured to be 96.0% during battery charging, and 96.9% during battery discharging. Moreover, this paper analyzes the effect of unavoidable dc-bias currents on the magnetic-flux saturation of the transformer. Finally, it provides the dc-dc converter loss breakdown with more focus on the LVS converter.
No takes yet. Share an insight, caveat, or question.
Tan et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: