February 11, 2011IEEE Transactions on Power Electronics485 citations

Design and Performance of a Bidirectional Isolated DC–DC Converter for a Battery Energy Storage System

View Full Paper
NTNadia M. L. TanTATakahiro AbeHAHirofumi Akagi

Key Points

Key points are not available for this paper at this time.

Abstract

This paper describes the design and performance of a 6-kW, full-bridge, bidirectional isolated dc-dc converter using a 20-kHz transformer for a 53.2-V, 2-kWh lithium-ion (Li-ion) battery energy storage system. The dc voltage at the high-voltage side is controlled from 305 to 355 V, as the battery voltage at the low-voltage side (LVS) varies from 50 to 59 V. The maximal efficiency of the dc-dc converter is measured to be 96.0% during battery charging, and 96.9% during battery discharging. Moreover, this paper analyzes the effect of unavoidable dc-bias currents on the magnetic-flux saturation of the transformer. Finally, it provides the dc-dc converter loss breakdown with more focus on the LVS converter.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tan et al. (2011) studied this question.

synapsesocial.com/papers/6a0c662d93c2b42b5c8865e0https://doi.org/10.1109/tpel.2011.2108317