Key result
ApoA-I mimetic peptide therapy increased aortic valve area and reduced aortic root wall thickness and collagen content in mice with aortic valve stenosis compared with placebo.
Why the study?
Does ApoA-I mimetic therapy improve aortic valve stenosis in mouse models?
RCT
Randomized
Does ApoA-I mimetic therapy improve aortic valve stenosis in mouse models?
ApoA-I mimetic therapy induces regression of aortic valve stenosis and reduces fibrosis in mouse models.
Answers are grounded in this paper and cite their sources.
Supports further preclinical research on ApoA-I mimetics in aortic stenosis; leaves open human translation.
BACKGROUND AND PURPOSE: We have shown that infusions of apolipoprotein A-I (ApoA-I) mimetic peptide induced regression of aortic valve stenosis (AVS) in rabbits. This study aimed at determining the effects of ApoA-I mimetic therapy in mice with calcific or fibrotic AVS. EXPERIMENTAL APPROACH: Apolipoprotein E-deficient (ApoE(-/-) ) mice and mice with Werner progeria gene deletion (Wrn(Δhel/Δhel) ) received high-fat diets for 20 weeks. After developing AVS, mice were randomized to receive saline (placebo group) or ApoA-I mimetic peptide infusions (ApoA-I treated groups, 100 mg·kg(-1) for ApoE(-/-) mice; 50 mg·kg(-1) for Wrn mice), three times per week for 4 weeks. We evaluated effects on AVS using serial echocardiograms and valve histology. KEY RESULTS: Aortic valve area (AVA) increased in both ApoE(-/-) and Wrn mice treated with the ApoA-I mimetic compared with placebo. Maximal sinus wall thickness was lower in ApoA-I treated ApoE(-/-) mice. The type I/III collagen ratio was lower in the sinus wall of ApoA-I treated ApoE(-/-) mice compared with placebo. Total collagen content was reduced in aortic valves of ApoA-I treated Wrn mice. Our 3D computer model and numerical simulations confirmed that the reduction in aortic root wall thickness resulted in improved AVA. CONCLUSIONS AND IMPLICATIONS: ApoA-I mimetic treatment reduced AVS by decreasing remodelling and fibrosis of the aortic root and valve in mice.
No takes yet. Share an insight, caveat, or question.
Trapeaux et al. (2013) conducted an RCT in Aortic valve stenosis. ApoA-I mimetic peptide vs. Saline (placebo) was evaluated on Aortic valve area (AVA) and valve histology. ApoA-I mimetic peptide therapy increased aortic valve area and reduced aortic root wall thickness and collagen content in mice with aortic valve stenosis compared with placebo.