Key result
Intuity and Perceval valves linked to lower peak gradients and better 1-year survival versus conventional valves.
Why the study?
The impact of rapid deployment and sutureless aortic bioprostheses on left ventricular mass regression remains unknown.
Do rapid deployment and sutureless aortic bioprostheses improve left ventricular mass regression and hemodynamics compared to conventional valves in patients with severe aortic stenosis?
Cohort (n=324)
No
Do rapid deployment and sutureless aortic bioprostheses improve left ventricular mass regression and hemodynamics compared to conventional valves in patients with severe aortic stenosis?
Rapid deployment aortic valves may offer superior hemodynamic performance, greater left ventricular mass regression, and improved 1-year survival compared to sutureless and conventional bioprostheses.
Observational data link rapid-deployment valves to better hemodynamics and survival; leaves open confirmation in randomized trials.
BACKGROUND: The use of rapid deployment and sutureless aortic prostheses is increasing. Previous reports have shown promising results on haemodynamic performance and mortality rates. However, the impact of these bioprostheses on left ventricular mass (LVM) regression remains unknown. We decided to study the changes in remodelling and LVM regression in isolated severe aortic stenosis treated with conventional or Perceval® or Intuity® valves. METHOD AND RESULTS: From January 2011 to January 2016, 324 bioprostheses were implanted in our centre. The collected characteristics were divided into 3 groups: conventional valves, Perceval®, and Intuity®, and they were analysed after 12 months. There were 183 conventional valves (56%), 72 Perceval® (22%), and 69 Intuity® (21.2%). The statistical analysis showed significant differences in transprosthetic postoperative peak gradient (23 [18-29] mm Hg vs. 21 [16-29] mm Hg and 18 [14-24] mm Hg, p < 0.001), ventricular mass electrical criteria regression (Sokolow and Cornell products), and 1-year survival (90 vs. 93% and 97%, log rank p value = 0.04) in conventional, Perceval®, and Intuity® groups. CONCLUSIONS: We observed differences in haemodynamic, electrocardiographic, and echocardiographic parameters related to the different types of prosthesis. Patients with the Intuity® prosthesis had the highest reduction in peak aortic gradient and the higher ventricular mass regression. Besides, patients with the Intuity® prosthesis had less risk of mortality during follow-up than the other two groups. Further studies are needed to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Taboada‐Martín et al. (2021) conducted a cohort in isolated severe aortic stenosis (n=324). Rapid deployment and sutureless aortic prostheses (Perceval® and Intuity®) vs. Conventional bioprostheses was evaluated on Transprosthetic postoperative peak gradient (p=< 0.001). Intuity® and Perceval® valves yielded lower postoperative peak gradients (18 and 21 mmHg vs 23 mmHg, p<0.001) and higher 1-year survival (97% and 93% vs 90%, p=0.04) than conventional valves.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: