Key result
Ischemic preconditioning raises pressure pain threshold but fails to improve resistance exercise performance versus control.
Why the study?
To determine the impact of ischemic preconditioning pressures on pressure pain threshold and resistance exercise performance, and whether performance changes could be explained by changes in pain threshold.
Does ischemic preconditioning at different pressures improve pressure pain threshold and resistance exercise performance?
RCT (n=39)
Randomized crossover
Does ischemic preconditioning at different pressures improve pressure pain threshold and resistance exercise performance?
Effect estimate: Difference 0.36 (110% AOP) and 0.377 (150% AOP) kg·m-2 (95% CI 0.18-0.54 (110% AOP); 0.15-0.59 (150% AOP))
Ischemic preconditioning at 110% and 150% of arterial occlusion pressure increases pain threshold but does not enhance resistance exercise performance.
Raises pain threshold without improving resistance exercise performance; challenges ergogenic use of ischemic preconditioning in strength training.
Kataoka, R, Song, JS, Yamada, Y, Hammert, WB, Seffrin, A, Spitz, RW, Wong, V, Kang, A, and Loenneke, JP. The impact of different ischemic preconditioning pressures on pain sensitivity and resistance exercise performance. J Strength Cond Res 38(5): 864-872, 2024-To determine (a) the impact of ischemic preconditioning pressures (applied as a % of arterial occlusion pressure [AOP]) on pressure pain threshold (PPT) and resistance exercise performance and (b) whether changes in performance could be explained by changes in PPT. Subjects ( n = 39) completed 4 protocols in a randomized order: (a) ischemic preconditioning (IPC) at 110% AOP (IPC 110%), (b) IPC at 150% AOP (IPC 150%), (c) IPC at 10% AOP (Sham), and (d) time-matched control (CON). Each protocol included 4 cycles of 5 minutes of occlusion followed by 5 minutes of reperfusion. Pressure pain threshold was taken before and after. Discomfort ratings were given at the end of each cycle. Every visit finished with 2 sets of 75-second maximal isokinetic unilateral elbow flexion or extension. Overall, IPC 110% and IPC 150% resulted in similar increases in PPT relative to CON [110%: difference of 0.36 (0.18, 0.54) kg·m -2 ; 150%: difference of 0.377 (0.15, 0.59) kg·m -2 ] and Sham. Both resulted in greater discomfort than Sham and CON, with IPC 150% inducing greater discomfort than IPC 110% (BF 10 : 14.74). There were no differences between the conditions for total work (BF 10 : 0.23), peak torque (BF 10 : 0.035), or average power (BF 10 : 0.159). We did not find evidence that PPT mediated performance. We did not detect changes in performance with 2 different relative pressures greater than AOP. Our mean applied pressures were lower than those used previously. There might be a minimal level of pressure (e.g., >150% of AOP) that is required to induce ergogenic effects of ischemic preconditioning.
No takes yet. Share an insight, caveat, or question.
Kataoka et al. (2024) conducted an RCT in Healthy subjects (n=39). Ischemic preconditioning (IPC) vs. Sham (10% AOP) and time-matched control was evaluated on Pressure pain threshold (PPT) (Difference 0.36 (110% AOP) and 0.377 (150% AOP) kg·m-2, 95% CI 0.18-0.54 (110% AOP); 0.15-0.59 (150% AOP)). Ischemic preconditioning at 110% and 150% arterial occlusion pressure increased pressure pain threshold compared to control but did not improve resistance exercise performance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: