PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 15, 1997Circulation166 citations

Improved Procedural Results of Coronary Angioplasty With Intravascular Ultrasound–Guided Balloon Sizing

View Full Paper
GSGregg W. StoneJHJohn M. HodgsonFGFrederick G. St. Goar

Key Points

Key points are not available for this paper at this time.

Abstract

BACKGROUND: Indiscriminate use of balloons larger than the angiographic reference segment lumen results in high rates of ischemic complications after percutaneous transluminal coronary angioplasty (PTCA). We hypothesized that angiographically unsuspected atheromatous remodeling with vessel expansion (the Glagov phenomenon) at and adjacent to PTCA target lesions would safely accommodate oversized balloons in selected patients undergoing PTCA with intravascular ultrasound (IVUS) guidance. METHODS AND RESULTS: After angiographically guided PTCA of 104 lesions in 102 patients, IVUS was performed, and if atheromatous remodeling was present, PTCA was repeated with larger balloons sized halfway between the lumen and external elastic membrane. Plaque occupied a mean of 51+/-15% of the angiographically "normal" reference segments. Further balloon upsizing by 0.25 to 1.25 mm was therefore performed in 76 lesions (73%), increasing the nominal balloon-to-artery ratio from 1.12+/-0.15 after standard PTCA to 1.30+/-0.17 after IVUS-guided PTCA (P<.0001). As a result, the angiographic minimal luminal diameter further increased from 1.95+/-0.49 to 2.21+/-0.47 mm, the % diameter stenosis fell from 28+/-15% to 18+/-14%, and the IVUS lumen area rose from 3.16+/-1.04 to 4.52+/-1.14 mm2 (all P<.0001). The incidence of angiographic dissection was not increased after IVUS-guided balloon upsizing (37% versus 40%, P=.67), and major complications occurred in only 2 patients (1.9%). CONCLUSIONS: The demonstration by IVUS of atheromatous remodeling permits the safe use of balloons traditionally considered oversized, resulting in significantly improved luminal dimensions without increased rates of dissection or ischemic complications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stone et al. (1997) studied this question.

synapsesocial.com/papers/6a0d00ee9a55ebeaa30cf11dhttps://doi.org/10.1161/01.cir.95.8.2044
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen1973 · 395 citations
  2. 2TRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSIS1978 · 1,351 citations
  3. 3Intracoronary ultrasound imaging: Correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty1993 · 360 citations
  4. 4Three dimensional reconstruction of cross sectional intracoronary ultrasound: clinical or research tool?1995 · 57 citations
  5. 5Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.1992 · 335 citations