Key result
Mapping recurrent AF reveals temporospatial stability with ~81% of sources in spatially conserved regions.
Why the study?
Are electrical propagation patterns and AF sources spatially conserved in patients with recurrent AF compared to their pre-ablation AF?
Cohort (n=29)
Are electrical propagation patterns and AF sources spatially conserved in patients with recurrent AF compared to their pre-ablation AF?
AF sources and electrical propagation patterns demonstrate temporospatial stability over 1-2 years in patients with recurrent AF after unsuccessful ablation.
Answers are grounded in this paper and cite their sources.
May inform repeat ablation targeting of conserved regions; hypothesis-generating pending prospective validation.
INTRODUCTION: Recurrent atrial fibrillation (AF) after ablation is associated with reconnection of initially isolated pulmonary vein (PV) trigger sites. Substrates are often targeted in addition to PVI, but it is unclear how substrates progress over time. We studied if substrates in recurrent AF are conserved or have developed de novo from pre-ablation AF. METHODS AND RESULTS: Of 137 patients undergoing Focal Impulse and Rotor Mapping (FIRM) at their index procedure for AF, 29 consecutive patients (60 ± 8 years, 79% persistent) recurred and were also mapped at repeat procedure (21 ± 20 months later) using carefully placed 64-pole baskets and RhythmView(TM) (Topera, Menlo Park, CA, USA) to identify AF sources and disorganized zones. Compared to index AF, recurrent AF had a longer cycle length (177 ± 21 vs. 167 ± 19 milliseconds, P = 0.01). All patients (100%) had 1 or more conserved AF rotors between procedures with surrounding disorganization. The number of sources was similar for recurrent AF post-PVI versus index AF (3.2 ± 1.4 vs. 3.1 ± 1.0, P = 0.79), but was lower for recurrent AF after FIRM+PVI versus index AF (4.4 ± 1.4 vs. 2.9 ± 1.7, P = 0.03). Overall, 81% (61/75) of AF sources lay in conserved regions, while 19% (14/75) were detected de novo. CONCLUSION: Electrical propagation patterns for recurrent AF after unsuccessful ablation are similar in individual patients to their index AF. These data support temporospatial stability of AF substrates over 1-2 years. Trials should determine the relative benefit of adding substrate mapping and ablation to PVI for recurrent AF.
No takes yet. Share an insight, caveat, or question.
Lalani et al. (2016) conducted a cohort in Recurrent atrial fibrillation (n=29). Focal Impulse and Rotor Mapping (FIRM) vs. Pre-ablation index mapping was evaluated on Proportion of AF sources in conserved regions. Mapping of recurrent atrial fibrillation revealed temporospatial stability of electrical substrates, with 81% of AF sources located in spatially conserved regions from the index procedure.
Synapse has enriched 10 related papers. Consider them for comparative context: