Key result
Higher peak sensitive troponin concentrations in patients admitted with syncope predicted an increased risk of serious outcome or death at 1 month (0% to 70% by quintile) and 1 year (10% to 85%).
Why the study?
Does plasma troponin concentration measured by a sensitive assay predict serious outcome or all-cause death in adult patients presenting to the ED with syncope?
Cohort (n=338)
Does plasma troponin concentration measured by a sensitive assay predict serious outcome or all-cause death in adult patients presenting to the ED with syncope?
In patients admitted from the ED with syncope, higher peak troponin concentrations measured by a sensitive assay are associated with an increased risk of serious outcomes and death at 1 month and 1 year.
May aid risk stratification in syncope admissions; hypothesis-generating and should not yet change practice.
AIMS: To assess whether plasma troponin concentration measured by a sensitive assay can predict 1-month and 1-year serious outcome, or all-cause death in patients presenting with syncope to the emergency department (ED). METHODS: Prospective cohort study of admitted adult patients presenting to the ED after an episode of syncope who had plasma troponin measured 12 h after syncope using the ARCHITECT STAT sensitive troponin I assay (Abbott Diagnostics). Primary endpoints were the composite endpoint of serious outcome or all-cause death at 1 month and 1 year. RESULTS: Between 1 March 2007 and 22 July 2008, 338 of 528 patients admitted from the ED with syncope had plasma troponin concentrations determined. Troponin concentrations were above the limit of detection in 261 (77%) patients. Patients numbering 120 (36%) had a troponin concentration ≥0.03 ng/ml (99th percentile of normal reference population), and 66 (20%) had concentrations ≥0.05 ng/ml (local diagnostic threshold for myocardial infarction). The proportion of patients with a composite serious outcome increased across patients stratified into quintiles based on peak troponin concentration at 1 month (0%, 9%, 13%, 26%, 70%) and at 1 year (10%, 22%, 26%, 52%, 85%). CONCLUSIONS: The majority of patients admitted from the ED with syncope have detectable plasma troponin concentrations. Peak troponin concentration was associated with increasing risk of serious outcome and death, and this risk increases with higher troponin concentrations. Troponin may have a future role in the risk stratification of patients with syncope.
No takes yet. Share an insight, caveat, or question.
Reed et al. (2012) conducted a cohort in Syncope (n=338). Sensitive troponin assay vs. Lower troponin concentrations was evaluated on Composite endpoint of serious outcome or all-cause death at 1 month and 1 year. Higher peak sensitive troponin concentrations in patients admitted with syncope predicted an increased risk of serious outcome or death at 1 month (0% to 70% by quintile) and 1 year (10% to 85%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: