Evaluates thermal performance of a hybrid air-conditioning system, indicating enhanced energy efficiency.
Buildings account for a substantial proportion of global energy consumption and greenhouse-gas emissions, largely due to the widespread use of conventional heating, ventilation, and air-conditioning (HVAC) systems. Hybrid systems that integrate passive and active technologies have emerged as a promising strategy for reducing energy demand while maintaining adequate indoor environmental conditions. This study evaluates the thermal and airflow performance of a hybrid air-conditioning system (HACS) that combines transparent thermal insulation (TTI) filled with R-410A refrigerant and a pig-fat-based organic phase-change material (PCM). Experimental measurements of heat flux, temperature, airflow velocity, and CO2 concentration were conducted in a controlled prototype system. In parallel, computational simulations were performed using computational fluid dynamics (CFD) and multizone airflow modeling. The hybrid system incorporates a TTI container acting as a solar absorber and a galvanized-steel PCM container filled with 10 kg of pig fat used as latent heat storage. Heat-flux measurements were obtained using an HFS-5 sensor connected to a data acquisition system, while airflow velocity and temperature were monitored with analog data loggers. Indoor CO2 concentrations were recorded using a dedicated CO2 meter and simulated using CONTAMW software version 3.4.0.8. The experimental results show that the TTI and PCM containers reached average heat-flux values of 77.04 W/m2 and 55.31 W/m2, respectively. Airflow within the system is induced by buoyancy forces arising from temperature gradients generated by heat transfer processes at the surfaces of the TTI and PCM, resulting in a mixed air stream with an average temperature of 37.54 °C during winter operation. Recorded CO2 concentrations remained between 290 and 413 ppm, indicating high indoor air quality levels. The overall experimental campaign spanned 6 years and 3 months. CFD simulations confirmed the airflow patterns and heat-transfer behavior observed experimentally. The findings demonstrate that hybrid air-conditioning systems combining refrigerant-filled transparent insulation with bio-based phase-change materials can effectively enhance passive thermal performance while maintaining acceptable indoor air quality. The integration of photovoltaic-powered ventilation systems could further the operational autonomy and overall energy efficiency of such hybrid systems.
No takes yet. Share an insight, caveat, or question.
Rodríguez et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: