Key result
CTAG device for acute complicated type B aortic dissection shows ~26% five-year mortality.
Why the study?
To evaluate the 5-year outcomes of TEVAR using the GORE conformable TAG thoracic endoprosthesis for acute, complicated type B aortic dissections and assess whether late aortic complications are avoided and remodeling sustained.
Does TEVAR with the GORE conformable TAG thoracic endoprosthesis improve long-term clinical and anatomic outcomes in patients with acute, complicated type B aortic dissections?
Observational (n=50)
Yes
Does TEVAR with the GORE conformable TAG thoracic endoprosthesis improve long-term clinical and anatomic outcomes in patients with acute, complicated type B aortic dissections?
TEVAR with the CTAG device for acute, complicated type B aortic dissection demonstrates favorable 5-year safety, sustained false lumen thrombosis, and positive aortic remodeling.
Supports CTAG TEVAR durability in acute complicated type B dissection; leaves open randomized confirmation of survival benefit.
Background Thoracic endovascular aortic repair (TEVAR) has become the treatment of choice for acute, complicated type B aortic dissections. The purpose of this study was to evaluate the 5-year outcomes of the GORE thoracic aortic graft (TAG) 08-01 study on TEVAR for acute, complicated type B aortic dissections using the GORE conformable TAG thoracic endoprosthesis (CTAG) and to establish if late aortic complications are avoided and remodeling is sustained. Methods From January 2010 to February 2017, 50 patients with acute, complicated type B aortic dissections were enrolled from 26 sites in the United States in this prospective, nonrandomized study. Patients underwent follow-up assessments postprocedure, at 1 month, 6 months, 1 year, and then yearly through 5 years. Device-related events, false lumen thrombosis, and aortic remodeling were assessed from computed tomography (CT) scans by a core laboratory. Results The all-cause mortality rate through 5 years was 26%. 4% of patients experienced late (>30 day) deaths that were attributable to aortic pathology. Secondary interventions were required in 22% of patients. In 87% of patients, complete false lumen thrombosis in the portion of the false lumen parallel to the stent-graft was observed. There was a significant 11 mm increase in the maximum true lumen diameter (P < 0.0001) and a 22 mm decrease in the maximum false lumen diameter (P < 0.0001) over 5 years. True lumen area was also increased by 221 mm² (P = 0.0003) over 5 years. There was no significant change in the false lumen area. There were no associations observed between patient outcomes and pretreatment indication for treatment (i.e., rupture with or without malperfusion or malperfusion alone). Conclusions Treatment of patients with advanced pathophysiology with the CTAG device resulted in favorable long-term clinical and anatomic outcomes. Complete thrombosis of the false lumen and positive aortic remodeling was sustained throughout the study. The low rate of late aortic events observed in this study demonstrates the safety, effectiveness, and the long-term durability of the CTAG device.
No takes yet. Share an insight, caveat, or question.
Desai et al. (2024) conducted an observational in Acute, complicated type B aortic dissections (n=50). GORE conformable TAG thoracic endoprosthesis (CTAG) was evaluated on All-cause mortality through 5 years. Treatment of acute, complicated type B aortic dissections with the CTAG device resulted in a 26% 5-year all-cause mortality rate and complete false lumen thrombosis in 87% of patients.