Key result
3D print model guides LV aneurysm repair, yielding precise volume agreement and NYHA class improvement.
Why the study?
Does a 3D print model optimize surgical planning and outcomes in a patient with a left ventricular aneurysm?
Case Report (n=1)
Does a 3D print model optimize surgical planning and outcomes in a patient with a left ventricular aneurysm?
A 3D print model of the heart can optimize surgical planning and individualize treatment for left ventricular aneurysm, leading to improved functional outcomes.
May support individualized LV aneurysm repair planning; leaves open generalizability and outcome benefits.
A 59-year-old woman was admitted to the emergency department for heart failure (HF), New York Heart Association (NYHA) IV, showing an anterior, evolved myocardial infarction (MI) with a wide apical left ventricular aneurysm (LVA), ejection fraction (EF) 24%, and global longitudinal strain (GLS) −5. 5% by echo. Cardiac magnetic resonance imaging (MRI) confirmed an apical LVA without thrombus, EF 20%, and a transmural delayed enhancement in the myocardium wall. Coronarography showed a three-vessel disease with occluded proximal left anterior descending (LAD) and proximal right coronary artery (RCA). Based on the cardiac CT scan, we decided to generate a three-dimensional (3D) print model of the heart, for better prediction of residual LV volumes. After LVA surgery plus complete functional revascularization, an optimal agreement was found between predicted and surgical residual LV end-diastolic (24.7 vs. 31.8 ml/m 2 ) and end-systolic (54.1 vs. 69.4 ml/m 2 ) volumes, with an improvement of NYHA class, from IV to I. The patient was discharged uneventfully and at 6- and 12-month follow-up, the NYHA class, and LV volumes were found unchanged. This is a second report describing the use of the 3D print model for the preoperative planning of surgical management of LVA; the first report was described by Jacobs et al. among three patients, one with a malignant tumor and the remaining two patients with LVA. This article focused on the use of the 3D print model to optimize surgical planning and individualize treatment of LVA associated with complete functional revascularization, leading to complete recovery of LV function with a favorable outcome.
No takes yet. Share an insight, caveat, or question.
Carrabba et al. (2022) conducted a case report in Left ventricular aneurysm and heart failure (n=1). Three-dimensional (3D) print model for surgical planning was evaluated on Agreement between predicted and surgical residual LV volumes and NYHA class improvement. A 3D print model optimized surgical planning for left ventricular aneurysm repair, yielding optimal agreement between predicted and surgical residual LV volumes and improving NYHA class from IV to I.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: