Key result
A new 3D echocardiography program accurately tracked left ventricular rotation in an ex vivo pig heart model, demonstrating strong correlation with actual global rotation.
Why the study?
Does a new 3D echocardiography program accurately track left ventricular rotation in an ex vivo pig heart model?
Does a new 3D echocardiography program accurately track left ventricular rotation in an ex vivo pig heart model?
Answers are grounded in this paper and cite their sources.
A new 3D echocardiography wall motion tracking program accurately measures left ventricular rotation in an ex vivo pig heart model.
OBJECTIVE: Left ventricular (LV) twist is manifested in oppositely directed apical and basal rotation. We studied a new 3-dimensional (3D) echocardiography program (wall motion tracking; Toshiba America Medical Systems, Inc, Tustin, CA) for left ventricular rotation. METHODS: We used a rotation model with a variable-speed motor to rotate hearts in a water bath. We studied 10 freshly harvested pig hearts, which were mounted on the rotary actuator of our twist phantom with the heart base rotating and the apex held fixed to avoid translational motion, at rotations of 0 degrees , 15 degrees , 20 degrees , and 25 degrees . Full-volume 3D image loops were acquired on a Toshiba Aplio Artida ultrasound system at a maximized frame rate. RESULTS: As the actual heart rotation increased, computed segmental and global rotation also increased accordingly, with the measured rotations of the basal and middle segments greater than that of the apex (both P < .001). Segmental and global rotation at all 3 levels correlated well with the actual rotation (base: r = 0.93; middle: r = 0.92; apex: r = 0.82; global: r = 0.95; all P < .001). CONCLUSIONS: The new 3D program tracked LV rotation accurately.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2010) studied Left ventricular rotation (n=10). 3D echocardiography program (wall motion tracking) vs. Actual rotation (0, 15, 20, and 25 degrees) was evaluated on Correlation of computed segmental and global rotation with actual rotation (r = 0.95, p=< .001). A new 3D echocardiography program accurately tracked left ventricular rotation in an ex vivo pig heart model, demonstrating strong correlation with actual global rotation.