Key result
Deep learning tool for real-time echocardiography guidance proposes adequate transducer movements ~75% of the time.
Why the study?
Reliability of 2-D ultrasound cardiac function measurements depends on proper transducer alignment with standard views and is operator-dependent.
Does a deep learning tool accurately suggest transducer movements to optimize apical standard views in echocardiography?
Does a deep learning tool accurately suggest transducer movements to optimize apical standard views in echocardiography?
A novel deep learning tool can accurately guide transducer movements in real-time to help users obtain standard apical echocardiography views.
May support real-time DL echo guidance; leaves open clinical adoption pending prospective validation.
Measurements of cardiac function such as left ventricular ejection fraction and myocardial strain are typically based on 2-D ultrasound imaging. The reliability of these measurements depends on the correct pose of the transducer such that the 2-D imaging plane properly aligns with the heart for standard measurement views and is thus dependent on the operator's skills. We propose a deep learning tool that suggests transducer movements to help users navigate toward the required standard views while scanning. The tool can simplify echocardiography for less experienced users and improve image standardization for more experienced users. Training data were generated by slicing 3-D ultrasound volumes, which permits simulation of the movements of a 2-D transducer. Neural networks were further trained to calculate the transducer position in a regression fashion. The method was validated and tested on 2-D images from several data sets representative of a prospective clinical setting. The method proposed the adequate transducer movement 75% of the time when averaging over all degrees of freedom and 95% of the time when considering transducer rotation solely. Real-time application examples illustrate the direct relation between the transducer movements, the ultrasound image and the provided feedback.
No takes yet. Share an insight, caveat, or question.
Pasdeloup et al. (2022) studied Echocardiography. Deep learning tool for transducer movement guidance was evaluated on Adequate transducer movement proposal (all degrees of freedom). A deep learning tool for real-time echocardiography guidance proposed adequate transducer movements 75% of the time across all degrees of freedom and 95% of the time for transducer rotation solely.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: