Answers are grounded in this paper and cite their sources.
In this paper, Shaft Misalignment of a Permanent Magnet Synchronous Motor (PMSM) is investigated, through a computationally-efficient method, Zoom-FFT. Conventional FFT computes a wide-range frequency spectrum while only a part of the frequency spectrum is necessary for fault detection. As conventional Zoom-FFT may lead to higher complexity for narrow fault-related frequency bands, a Two Stage Zoom-FFT analysis has been proposed, which offers a low-complexity solution, taking advantage of the current measurement sensors integrated in the PMSM drive system. The proposed method has been validated through experimental testing under different operating conditions.
No takes yet. Share an insight, caveat, or question.
Koutrakos et al. (2023) studied this question.