Key result
Optimized alarm management reduces fatigue by filtering the ~90% of false ECG alarms.
Implementing unit-specific alarm management strategies, such as proper electrode placement and customized settings, is recommended to mitigate the patient safety risks associated with alarm fatigue.
Answers are grounded in this paper and cite their sources.
May support unit alarm protocols to reduce fatigue; leaves open prospective trials on outcomes.
Alarm fatigue is a patient safety risk, occurring when clinicians are exposed to excessive numbers of alarms, particularly false and clinically insignificant alarms. This overexposure results in sensory overload and desensitization to alarms. Consequently, response to alarms may be delayed or alarms may be missed altogether. Patients’ deaths have been attributed to alarm fatigue when a serious clinical event was missed because the alarm was not heard or was assumed to be false.1 In recent studies,2,3 from 89% to 99% of electrocardiographic (ECG) monitor alarms were found to be false or clinically insignificant. To date, clinical strategies to reduce alarms and alarm fatigue have been focused on ECG and oxygen saturation (Spo2) alarms. However, evidence for these strategies is limited. Interventions presented here are primarily supported by expert opinion and/or have demonstrated success in quality improvement projects. To reduce false and clinically insignificant alarms and alarm fatigue, clinical units should assess their alarm burden and select interventions that address unit-specific needs.Provide proper skin preparation for and placement of ECG electrodes.Use proper Spo2 probe and placement.Check alarm settings at the start of each shift, with any change in the patient’s condition, and with any change in caregiver.Customize alarm parameter settings for individual patients in accordance with unit or hospital policy.Organize an interprofessional alarm management team.Develop unit-specific default parameters and alarm management policies.Provide ongoing education on monitoring systems and alarm management for unit staff.Develop policies/procedures for monitoring only those patients with clinical indications for monitoring.
No takes yet. Share an insight, caveat, or question.
A 2018 study conducted a review in Alarm fatigue. Alarm management strategies was evaluated. Alarm management strategies, including proper electrode placement and customized settings, are recommended to reduce alarm fatigue, as 89% to 99% of ECG alarms are false or insignificant.
Synapse has enriched 10 related papers. Consider them for comparative context: