Why the study?
Heart failure is a major challenge in sub-Saharan Africa, where cardiac resynchronization therapy is in its infancy and very few studies have been conducted.
Cross-Sectional (n=12)
No
CRT implantation is feasible and improves clinical and echocardiographic parameters in heart failure patients in Sub-Saharan Africa, though financial barriers severely limit access.
Suggests CRT feasibility in Sub-Saharan Africa; leaves open need for larger prospective trials before practice change.
Background: Heart failure is a major public health challenge in sub-Saharan Africa. In patients with chronic Heart Failure and cardiac desynchrony, studies have suggested that cardiac resynchronization, can improve cardiac function and the quality of life of patients. However, in Sub-Saharan Africa, very few studies have been done on cardiac resynchronization which is in its infancy. The aim of this study is to report the local data from our hospital. Method: It was a transversal, descriptive and analytical study conducted from November 2019 to September 2022 at the Cardiology Department of the Principal Hospital of Dakar. Results: Twelve patients were implanted for Cardiac Resynchronization Therapy (CRT). The sex ratio was 8 males/4 females. The average age was 67 ± 11 years. Ten patients had non-ischemic heart disease and the two others had ischemic one. All of them had NYHA III or IV scores before CRT. The Quality of Life (QOL) was judged as poor by all of the patients. The average duration of QRS was 156 ± 9 ms. 27.9% ± 5% was the mean Left Ventricular ejection fraction (LVEF). Complications occur in 3/12 patients (25%). It was one CS vein dissection, one micro LV lead dislodgement and one phrenic nerve stimulation. Nine patients, who were considered as responders, had an improvement of QOL and NYHA, the LVEF increased and the end-diastolic dimension, and the duration of the QRS interval all decreased. Two patients do not respond and one (1) who had permanent atrial fibrillation, was a secondary responder after an atrioventricular junction ablation. Conclusion: Cardiac resynchronization is a therapy that improves the QOL of patients, the LVEF and reduces the duration of the QRS interval. However, this procedure is not without risk of complications. In sub-Saharan Africa, the major challenge is to improve the financial accessibility of this therapy for the population.
No takes yet. Share an insight, caveat, or question.
Dia et al. (2023) conducted a cross-sectional in Heart Failure with cardiac desynchrony (n=12). Cardiac Resynchronization Therapy (CRT) was evaluated on Response to CRT (improvement of QOL, NYHA, LVEF, and decreased QRS duration).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: