Key result
Fixed methods outperform dynamic methods for constructing VKA episodes by yielding person-time ratios closer to 1.0.
Why the study?
Constructing vitamin K antagonist treatment episodes from dispensed prescriptions in pharmaco-epidemiological studies is challenging due to large variability in therapeutic dose.
Observational (n=30,000)
Yes
Fixed methods are superior to dynamic methods for estimating vitamin K antagonist exposure from dispensing data when exact prescribed doses are unavailable.
Answers are grounded in this paper and cite their sources.
Fixed methods may reduce VKA exposure misclassification in dispensing-based cohorts; leaves validation against clinical outcomes open.
BACKGROUND: In pharmaco-epidemiological studies using vitamin K antagonist (VKA) exposure, constructing treatment episodes based on dispensed prescriptions is challenging, particularly due to the large variability in therapeutic dose. OBJECTIVES: To validate different methods of constructing VKA treatment episodes based on dispensed prescriptions, using VKA exposure based on international normalized ratio (INR) measurements as a reference. METHODS: Data from five Dutch anticoagulation clinics were linked to VKA dispensing data from Statistics Netherlands. Three random samples of 10 000 VKA users between 2013 and 2019 were used to compare the construction of VKA treatment episodes based on dispensings, applying fixed or dynamic methods, against the reference of exposure based on INR measurements. A total of 60 different methods were validated by computing the percentage of INR measurements occurring outside dispensing-based VKA treatment episodes, the ratio of VKA-exposed person-time based on dispensings vs. INR measurements, and the number of dispensing-based episodes. RESULTS: Depending on the method used to construct treatment episodes, 14.8%-42.2% of the INR measurements were not covered by a dispensing-based episode. The VKA-exposed person-time ratio ranged between 0.73 and 1.13, and there was substantial variability in the number of dispensing-based episodes. Fixed methods resulted in a lower percentage of INR measurements outside the dispensing-based episodes, a VKA-exposed person-time ratio closer to 1.0, and a lower number of constructed episodes. CONCLUSION: Fixed methods performed better than dynamic methods when classifying VKA exposure based on dispensing data. Our findings may guide other researchers working with VKA dispensing data, especially when the tablets dispensed or the prescribed dose are unavailable.
No takes yet. Share an insight, caveat, or question.
Kempers et al. (2025) conducted an observational in Vitamin K antagonist users (n=30,000). Fixed methods for constructing VKA treatment episodes vs. Dynamic methods was evaluated on Percentage of INR measurements occurring outside dispensing-based VKA treatment episodes and ratio of VKA-exposed person-time. Fixed methods for constructing vitamin K antagonist treatment episodes from dispensing data outperformed dynamic methods, yielding a VKA-exposed person-time ratio closer to 1.0.
Synapse has enriched 10 related papers. Consider them for comparative context: