Answers are grounded in this paper and cite their sources.
The conditions for the occurrence of partial discharges are analysed and shown to be governed by the trapping of charged particles on the insulation surface. According to the instant of trapping, each discharge is constituted either by a series of single avalanches or by a sort of degenerated spark which constitutes the partial discharge. Charge deposits form a sharply defined site which is visible on powdering. If the deposited charge is positive, the site is star-shaped and its shape and size strongly depend on the electronegativity of the gas. If the discharge is negative, the site is circular in all the gases. By measuring the site diameter it is possible in several cases to calculate the capacity involved in the discharge, and consequently the energy of it. This technique is used to study the explosivity of vapours in spaces bounded by charged insulators.
No takes yet. Share an insight, caveat, or question.
H. Bertein (1973) studied this question.