Key result
Larger PV ostium and lower freezing temperatures link to higher PV narrowing risk after cryoballoon ablation.
Cohort (n=74)
Effect estimate: OR 1.773 (larger PV ostium); OR 1.137 (lower minimum freezing temperature)
p-value: p=0.01; <0.001
Pulmonary vein narrowing is frequently observed 3 months after cryoballoon ablation for atrial fibrillation, with the risk increased by larger PV ostia and lower freezing temperatures.
May warrant caution during cryoballoon ablation in large ostia; hypothesis-generating for procedural optimization in AF.
Background— In contrast with traditional radiofrequency ablation, little is known about the influence of cryoballoon ablation on the morphology of pulmonary veins (PVs). We evaluated the influence of cryoballoon ablation on the PV dimension (PVD) and investigated the factors associated with a reduction of the PVD. Methods and Results— Seventy-four patients who underwent cryoballoon ablation for paroxysmal atrial fibrillation were included in the present study. All subjects underwent contrast-enhanced computed tomography both before and at 3 months after the procedure. The PVD (cross-sectional area) was measured using a 3-dimensional electroanatomical mapping system. Each PV was evaluated according to the PVD reduction rate (ΔPVD), which was calculated as follows: (1−post-PVD/pre-PVD)×100 (%). Ninety-two percent of the PVs (271/296) were successfully isolated only by cryoballoon ablation; the remaining 8% of the PVs required touch-up ablation and were excluded from the analysis. Mild (25%–50%), moderate (50%–75%), and severe (≥75%) ΔPVD values were observed in 87, 14, and 3 PVs, respectively, including 1 case with severe left superior PV stenosis (ΔPVD: 94%) in a patient who required PV angioplasty. In multivariable analysis, a larger PV ostium and lower minimum freezing temperature during cryoballoon ablation were independently associated with PV narrowing (odds ratio, 1.773; P =0.01; and odds ratio, 1.137; P <0.001, respectively). Conclusions— A reduction of the PVD was often observed after cryoballoon ablation for atrial fibrillation. A larger PV ostium and lower minimum freezing temperature during cryoballoon ablation were associated with an increased risk of PVD reduction.
No takes yet. Share an insight, caveat, or question.
Narui et al. (2017) conducted a cohort in paroxysmal atrial fibrillation (n=74). Cryoballoon ablation was evaluated on Pulmonary vein narrowing (OR 1.773 (larger PV ostium); OR 1.137 (lower minimum freezing temperature), p=0.01; <0.001). A larger PV ostium and lower minimum freezing temperature during cryoballoon ablation were independently associated with PV narrowing (OR 1.773, P=0.01 and OR 1.137, P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: