Key result
Bedside femoral pressure reliably estimates effective arterial elastance and tracks decreases after saline in fluid responders.
Why the study?
Bedside estimates of effective arterial elastance needed validation in critically ill patients, along with documentation of its added value as an index of left ventricular afterload.
Can effective arterial elastance be reliably estimated at the bedside using femoral or radial arterial catheters in critically ill patients, and how does it respond to fluid administration?
Cohort (n=80)
Can effective arterial elastance be reliably estimated at the bedside using femoral or radial arterial catheters in critically ill patients, and how does it respond to fluid administration?
Answers are grounded in this paper and cite their sources.
In critically ill patients, bedside effective arterial elastance can be reliably estimated using femoral systolic pressure (0.9 x systolic femoral pressure/stroke volume) to assess ventricular-arterial coupling, but it should not be used in isolation as an index of left ventricular afterload.
Objectives: First, to validate bedside estimates of effective arterial elastance = end-systolic pressure/stroke volume in critically ill patients. Second, to document the added value of effective arterial elastance, which is increasingly used as an index of left ventricular afterload. Design: Prospective study. Setting: Medical ICU. Patients: Fifty hemodynamically stable and spontaneously breathing patients equipped with a femoral (n = 21) or radial (n = 29) catheter were entered in a “comparison” study. Thirty ventilated patients with invasive hemodynamic monitoring (PiCCO-2; Pulsion Medical Systems, Feldkirchen, Germany), in whom fluid administration was planned were entered in a “ dynamic” study. Interventions: In the “dynamic” study, data were obtained before/after a 500 mL saline administration. Measurements and Main Results: According to the “cardiocentric” view, end-systolic pressure was considered the classic index of left ventricular afterload. End-systolic pressure was calculated as 0.9 × systolic arterial pressure at the carotid, femoral, and radial artery level. In the “comparison” study, carotid tonometry allowed the calculation of the reference effective arterial elastance value (1.73 ± 0.62 mm Hg/mL). The femoral estimate of effective arterial elastance was more accurate and precise than the radial estimate. In the “dynamic” study, fluid administration increased stroke volume and end-systolic pressure, whereas effective arterial elastance (femoral estimate) and systemic vascular resistance did not change. Effective arterial elastance was related to systemic vascular resistance at baseline (r = 0.89) and fluid-induced changes in effective arterial elastance and systemic vascular resistance were correlated (r = 0.88). In the 15 fluid responders (cardiac index increases ≥ 15%), fluid administration increased end-systolic pressure and decreased effective arterial elastance and systemic vascular resistance (each p < 0.05). In the 15 fluid nonresponders, end-systolic pressure increased (p < 0.05), whereas effective arterial elastance and systemic vascular resistance remained unchanged. Conclusions: In critically ill patients, effective arterial elastance may be reliably estimated at bedside (0.9 × systolic femoral pressure/stroke volume). We support the use of this validated estimate of effective arterial elastance when coupled with an index of left ventricular contractility for studying the ventricular-arterial coupling. Conversely, effective arterial elastance should not be used in isolation as an index of left ventricular afterload.
No takes yet. Share an insight, caveat, or question.
Jozwiak et al. (2019) conducted a cohort in Critically ill patients in a medical ICU (n=80). Bedside estimation of effective arterial elastance (0.9 x systolic femoral/radial pressure / stroke volume) and 500 mL saline fluid challenge vs. Reference effective arterial elastance via carotid tonometry; fluid responders vs nonresponders was evaluated on Validation of bedside effective arterial elastance estimates and changes after fluid administration (r = 0.89, p=<0.05). Femoral estimation of effective arterial elastance was more accurate than radial and correlated tightly with systemic vascular resistance at baseline (r=0.89) and after fluid challenge (r=0.88).