Key result
Signal-averaged recordings using individual XYZ leads, visual identification, and finite impulse response digital filters showed concordance with epicardial recordings within 5 msec in 11 of 13 dogs.
Why the study?
Does modified SAECG analysis accurately identify the end of ventricular activation compared to epicardial mapping in an animal model?
Does modified SAECG analysis accurately identify the end of ventricular activation compared to epicardial mapping in an animal model?
Modified SAECG approaches, including individual XYZ lead analysis and visual identification, can accurately identify the end of ventricular activation within 5 msec of epicardial mapping in an animal model.
Provides preclinical support for modified SAECG accuracy; leaves open clinical validation against invasive mapping in patients.
INTRODUCTION: Identification of the end of the QRS is perhaps the single most important feature obtained from the high resolution signal-averaged electrocardiogram (SAECG). This point relies on computer algorithms to select a point above the noise levels. Prior studies to substantiate this approach using electrograms for comparison have demonstrated many examples of the body surface recordings failing to detect the full extent of the late potentials. METHODS AND RESULTS: An animal model that generates late potentials was used in conjunction with epicardial cardiac mapping system to systematically examine the reasons for these failures. In 11 of 13 dogs we found a concordance between the signal-averaged recordings and the epicardial recordings within 5 msec. The two discordant studies were attributed to a failure of epicardial mapping to record all late potential sources. Also, a means of accurately comparing measurements from the two recording technologies was required in this study as well as a new definition for identifying the end of activation currents in epicardial electrograms. CONCLUSION: To achieve these results required approaches different from those used in the clinical setting to record the SAECG. These include: (1) the analysis of individual XYZ leads as opposed to the vector magnitude derived from these leads; (2) visual identification of very low level signals, as automatic algorithms often fail to detect low level signals; and (3) the use of finite impulse response digital filters instead of the bidirectional Butterworth filter.
No takes yet. Share an insight, caveat, or question.
Berbari et al. (1994) studied Late potentials (n=13). Signal-averaged electrocardiogram (SAECG) with modified approaches vs. Epicardial cardiac mapping system was evaluated on Concordance between signal-averaged recordings and epicardial recordings within 5 msec. Signal-averaged recordings using individual XYZ leads, visual identification, and finite impulse response digital filters showed concordance with epicardial recordings within 5 msec in 11 of 13 dogs.