Comparing signal-averaged ECG with multielectrode cardiac mapping in a canine myocardial infarction model showed concordance in timing of late potentials in 10 of 13 dogs.
Signal-averaged ECG correlates well with epicardial mapping for identifying late potentials in a canine MI model, though improvements in signal recovery are needed.
Supports signal-averaged ECG correlation with mapping in canine MI; leaves open human validation for arrhythmia risk stratification.
Cardiac late potentials, measured with the signal-averaged ECG, have been strongly correlated with potentially lethal ventricular arrhythmias. A key factor in identifying and quantifying these late potentials is the determination of the end of ventricular depolarization. The goal of this study was to identify the latest moment of ventricular depolarization by comparing a signal-averaged ECG with multielectrode cardiac mapping of infarct regions. The four-day-old, canine myocardial infarction model was used. In 10 of 13 dogs studied, a concordance in timing between the epicardial array and signal-averaged XYZ surface leads was found. In three dogs the lack of concordance is attributed to a poor signal-to-noise ratio of the surface-signal average and its distortion by high-pass filtering, which often eliminates enough signal energy to preclude identification. Further improvements in low-level signal recovery and postaveraging analysis are needed to ensure that cardiac late potentials are fully identified from body-surface recordings.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Berbari et al. (2003) studied Myocardial infarction (canine model) (n=13). Signal-averaged ECG vs. Multielectrode cardiac mapping (epicardial array) was evaluated on Concordance in timing between epicardial array and signal-averaged XYZ surface leads. Comparing signal-averaged ECG with multielectrode cardiac mapping in a canine myocardial infarction model showed concordance in timing of late potentials in 10 of 13 dogs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: