Key result
3D mapping-guided conduction system pacing improves LV function and narrows QRS in a single patient.
Why the study?
Conduction system pacing for CRT requires high precision targeting narrow cardiac structures, but long fluoroscopy times remain a major limitation.
Does conduction system pacing guided by 3D electro-anatomical mapping improve clinical status and left ventricular function in a patient with non-ischemic dilated cardiomyopathy and left bundle branch block?
Case Report (n=1)
Does conduction system pacing guided by 3D electro-anatomical mapping improve clinical status and left ventricular function in a patient with non-ischemic dilated cardiomyopathy and left bundle branch block?
3D electro-anatomical mapping is a valuable tool to guide conduction system pacing, achieving narrow QRS and clinical improvement with low fluoroscopy exposure in complex anatomies.
Answers are grounded in this paper and cite their sources.
May support 3D mapping-guided pacing in complex cases; hypothesis-generating and requires prospective validation.
INTRODUCTION: Biventricular pacing has been the gold standard for cardiac resynchronization therapy in patients with left bundle branch block and severely reduced left ventricular ejection fraction for decades. However, in the past few years, this role has been challenged by the promising results of conduction system pacing in these patients, which has proven non-inferior and, at times, superior to biventricular pacing regarding left ventricular function outcomes. One of the most important limitations of both procedures is the long fluoroscopy times. CASE DESCRIPTION: We present the case of a 60-year-old patient with non-ischemic dilated cardiomyopathy and left bundle branch block in whom conduction system pacing was chosen as the first option for resynchronization therapy. A 3D electro-anatomical mapping system was used to guide the lead to the His bundle region, where correction was observed at high amplitudes, and afterward to the optimal septal penetration site. After reaching the left endocardium, left bundle branch pacing achieved a narrow, paced QRS complex with low fluoroscopy exposure. The three-month follow-up showed a significant improvement in clinical status and left ventricular function. CONCLUSION: Since conduction system pacing requires a great deal of precision, targeting specific, narrow structures inside the heart, 3D mapping is a valuable tool that increases the chances of success, especially in patients with complex anatomies, such as those with indications for cardiac resynchronization therapy.
No takes yet. Share an insight, caveat, or question.
Pestrea et al. (2023) conducted a case report in Non-ischemic dilated cardiomyopathy and left bundle branch block (n=1). Conduction system pacing guided by 3D electro-anatomical mapping was evaluated on Clinical status and left ventricular function. In a 60-year-old patient, conduction system pacing guided by 3D electro-anatomical mapping achieved a narrow QRS complex and significant improvement in clinical status and LV function at 3 months.