Key result
Accounting for microscopic susceptibility gradients lowers supraclavicular fat fraction by ~1.3% versus traditional spectral models.
Why the study?
Does a water-fat spectral model accounting for susceptibility-induced variations improve the accuracy of fat fraction quantification in supraclavicular fat compared to traditional models?
Observational (n=14)
Does a water-fat spectral model accounting for susceptibility-induced variations improve the accuracy of fat fraction quantification in supraclavicular fat compared to traditional models?
Microscopic susceptibility gradients in supraclavicular fat can cause variations in water-fat frequency separation, potentially leading to fat fraction quantification errors of up to 5% when using traditional spectral models.
Answers are grounded in this paper and cite their sources.
Requires caution interpreting supraclavicular fat fraction on standard MRI; leaves open clinical utility of susceptibility-corrected models.
BACKGROUND: Susceptibility differences between fat and water can cause changes in the water-fat frequency separation that can negatively affect the accuracy of fat fraction techniques. This may be especially relevant for brown adipose tissue, as MRI fat fraction techniques have been proposed for its detection. PURPOSE: To assess the effect of microscopic magnetic susceptibility gradients on the water-fat frequency separation and its impact on chemical-shift-based fat fraction quantification techniques in the supraclavicular fat, where brown adipose tissue is commonly found in humans. STUDY TYPE: Prospective. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Subjects: 11 healthy volunteers, mean age of 26 and mean BMI of 23, three overweight volunteers, mean age of 38 and mean BMI of 33. Phantoms: bovine phantom and intralipid fat emulsion. Simulations: various water-fat distributions. FIELD STRENGTH/SEQUENCE: Six-echo gradient echo chemical-shift-encoded sequence at 3T. ASSESSMENT: Fat fraction values as obtained from a water-fat spectral model accounting for susceptibility-induced water-fat frequency variations were directly compared to traditional spectral models that assume constant water-fat frequency separation. STATISTICAL TESTS: Two-tail t-tests were used for significance testing (p < 0.05.) A Bayesian Information Criterion difference of 6 between fits was taken as strong evidence of an improved model. RESULTS: Phantom experiments and simulation results showed variations of the water-fat frequency separation up to 0.4 ppm and 0.6 ppm, respectively. In the supraclavicular area, the water-fat frequency separation produced by magnetic susceptibility gradients varied by as much as ±0.4 ppm, with a mean of 0.08 ± 0.14 ppm, producing a mean difference in fat fraction of -1.26 ± 5.26%. DATA CONCLUSION: In the supraclavicular fat depot, microscopic susceptibility gradients that exist within a voxel between water and fat compartments can produce variations in the water-fat frequency separation. These variations may produce fat fraction quantification errors of 5% when a spectral model with a fixed water-fat frequency separation is applied, which could impact MR brown fat techniques. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:141-151.
No takes yet. Share an insight, caveat, or question.
McCallister et al. (2018) conducted an observational in Brown adipose tissue detection (n=14). Water-fat spectral model accounting for susceptibility-induced variations vs. Traditional spectral models assuming constant separation was evaluated on Difference in fat fraction quantification (Mean difference -1.26%). Accounting for microscopic susceptibility gradients in supraclavicular fat produced a mean difference in fat fraction of -1.26 ± 5.26% compared to traditional spectral models.
Synapse has enriched 10 related papers. Consider them for comparative context: