Key result
CSPAMM myocardial tagging with an interleaved spiral sequence enabled high-quality grid-tagged images with a tagline distance as low as 4 mm in a single breath-hold in 10 healthy subjects.
Why the study?
Does CSPAMM myocardial tagging with an interleaved spiral imaging sequence provide high-quality images and tag persistence in healthy adults?
Does CSPAMM myocardial tagging with an interleaved spiral imaging sequence provide high-quality images and tag persistence in healthy adults?
CSPAMM myocardial tagging with an interleaved spiral imaging sequence allows for high-quality, high-temporal-resolution imaging with tag persistence throughout the cardiac cycle in a single breath-hold.
No takes yet. Share an insight, caveat, or question.
Enables finer-resolution tagging in healthy volunteers; leaves open validation for clinical strain assessment.
Ryf et al. (2004) studied Healthy (n=10). CSPAMM myocardial tagging with an interleaved spiral imaging sequence was evaluated on Image quality and tag persistence. CSPAMM myocardial tagging with an interleaved spiral sequence enabled high-quality grid-tagged images with a tagline distance as low as 4 mm in a single breath-hold in 10 healthy subjects.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: