Key result
Noninvasive machine learning model estimates low-to-moderate exercise blood lactate with ~0.52 mmol/L error.
Why the study?
The study aimed to establish a mathematical model to estimate blood lactate concentration noninvasively during constant work rate exercise of various intensities based on cardiopulmonary variables, exercise intensity, and anthropometric elements.
Does a mathematical model using noninvasive cardio-respiratory parameters accurately estimate blood lactate concentration during constant work rate exercise in healthy adults?
Observational (n=31)
No
Does a mathematical model using noninvasive cardio-respiratory parameters accurately estimate blood lactate concentration during constant work rate exercise in healthy adults?
A mathematical model using noninvasive cardio-respiratory parameters can accurately estimate blood lactate concentration during constant work rate exercise, with potential applications in endurance training.
May enable noninvasive lactate monitoring during exercise; hypothesis-generating pending prospective validation in athletes and patients.
We hypothesized that blood lactate concentration([Lac] blood ) is a function of cardiopulmonary variables, exercise intensity and some anthropometric elements during aerobic exercise. This investigation aimed to establish a mathematical model to estimate [Lac] blood noninvasively during constant work rate (CWR) exercise of various intensities. 31 healthy participants were recruited and each underwent 4 cardiopulmonary exercise tests: one incremental and three CWR tests (low: 35% of peak work rate for 15 min, moderate: 60% 10 min and high: 90% 4 min). At the end of each CWR test, venous blood was sampled to determine [Lac] blood . 31 trios of CWR tests were employed to construct the mathematical model, which utilized exponential regression combined with Taylor expansion. Good fitting was achieved when the conditions of low and moderate intensity were put in one model; high-intensity in another. Standard deviation of fitting error in the former condition is 0.52; in the latter is 1.82 mmol/liter. Weighting analysis demonstrated that, besides heart rate, respiratory variables are required in the estimation of [Lac] blood in the model of low/moderate intensity. In conclusion, by measuring noninvasive cardio-respiratory parameters, [Lac] blood during CWR exercise can be determined with good accuracy. This should have application in endurance training and future exercise industry.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2019) conducted an observational in Healthy participants (n=31). Machine learning-based mathematical model using noninvasive cardio-respiratory parameters vs. Measured venous blood lactate concentration was evaluated on Standard deviation of fitting error for estimated blood lactate concentration (low/moderate intensity). A machine learning-based mathematical model using noninvasive cardio-respiratory parameters accurately estimated blood lactate concentration during low and moderate intensity exercise with a fitting error standard deviation of 0.52 mmol/liter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: