Nuclear power plants operate an early warning system that classifies signal groups based on the correlation between measurement signals and that learns past normal operation data patterns to detect fault signs through comparison with real-time data. A suitable technology expansion is needed in the startup operation since the signal distribution varies complexly after the planned preventive maintenance to reaching the normal operation. In this paper, we propose a fault detection method that applies the approximate nearest neighbor search technique to secure sophisticated prediction performance even in signal groups with weak correlations. As a result of comparing and analyzing the difference between predicted and actual values by selecting signal groups that represent the startup operation including increasing trend, decreasing trend, and different physical unit groups, it was shown that residual changes can be detected at a faster time point compared to existing techniques. Since the method can generate alarms for fault detection early, it can be supplemented to safely reach the normal operation even in the startup operation.